Results 91 to 100 of about 41,342 (356)

Model-based Pre-clinical Trials for Medical Devices Using Statistical Model Checking [PDF]

open access: yesarXiv, 2021
Clinical trials are considered as the golden standard for medical device validation. However, many sacrifices have to be made during the design and conduction of the trials due to cost considerations and partial information, which may compromise the significance of the trial results. In this paper, we proposed a model-based pre-clinical trial framework
arxiv  

Emergency medicine and general practice [PDF]

open access: yes, 2005
Emergency Medicine and Immediate Medical Care are relatively new specialties. In Malta, there is quite a considerable area of overlap between these specialties and general practice.
Abela, Gunther
core  

Prehospital randomised assessment of a mechanical compression device in cardiac arrest (PaRAMeDIC) trial protocol [PDF]

open access: yes, 2010
Background Survival after out-of-hospital cardiac arrest is closely linked to the quality of CPR, but in real life, resuscitation during pre-hospital care and ambulance transport is often suboptimal.
Cooke, Matthew   +10 more
core   +5 more sources

Clinical characteristics and long‐term outcomes in patients with apical hypertrophic cardiomyopathy

open access: yesESC Heart Failure, EarlyView.
Abstract Aims As a special type of hypertrophic cardiomyopathy (HCM), apical HCM (ApHCM) has different clinical characteristics while its nature history and prognosis are not well recognized. We aimed to describe the characteristics and outcomes of ApHCM and identify predictors of adverse outcomes.
Meng Guo   +3 more
wiley   +1 more source

The implanted defibrillator: relation of defibrillating lead configuration and clinical variables to defibrillation threshold

open access: yesJournal of the American College of Cardiology, 1985
Forty-two defibrillating lead systems for the automatic implantable defibrillator were implanted and tested in 41 patients. Two basic lead configurations were used: 1) spring-patch, consisting of a transvenous superior vena cava spring electrode as the anode and an apical or left lateral ventricular patch electrode (either small [13.9 cm2] or large [27.
Peter D. Chapman   +3 more
openaire   +3 more sources

Selecting patients with nonischemic dilated cardiomyopathy for ICDs [PDF]

open access: yes, 2017
No abstract ...
Cleland, John G.F.   +2 more
core   +1 more source

Prognostic value of left atrial strain in acute and chronic heart failure: A meta‐analysis

open access: yesESC Heart Failure, EarlyView.
The prognostic evaluation of heart failure (HF) beyond ejection fraction remains challenging. Moreover, reliable prognosticators in chronic HF sometimes lose their value in acute settings or vice versa. Speckle tracking echocardiography offers new sensitive parameters for prognostic stratification in heart failure with reduced and preserved ejection ...
Maria Concetta Pastore   +12 more
wiley   +1 more source

An Innovative Wireless Cardiac Rhythm Management (iCRM) System [PDF]

open access: yes, 2014
In this paper, we propose a wireless Communicator to manage and enhance a Cardiac Rhythm Management System. The system includes: (1) an on-body wireless Electrocardiogram (ECG), (2) an Intracardiac Electrogram (EGM) embedded inside an Implantable Cardioverter/Defibrillator, and (3) a Communicator (with a resident Learning System). The first two devices
arxiv   +1 more source

Dilated cardiomyopathy evaluation with Imagenomics: combining multimodal cardiovascular imaging and genetics

open access: yesESC Heart Failure, EarlyView.
Systematic approach to dilated cardiomyopathy diagnosis. Dilated cardiomyopathy is a clinical diagnosis characterized by the presence of left ventricular dilatation and systolic disfunction unexplained by abnormal loading conditions or coronary artery disease.
Kristian Galanti   +14 more
wiley   +1 more source

Electrostriction Effects During Defibrillation [PDF]

open access: yesAmerican Journal of Undergraduate Research, VOL. 6, NO. 2, 9-17 (2007), 2011
Background-The electric field applied to the heart during defibrillation causes mechanical forces (electrostriction), and as a result the heart deforms. This paper analyses the physical origin of the deformation, and how significant it is. Methods-We represent the heart as an anisotropic cylinder.
arxiv  

Home - About - Disclaimer - Privacy