Prospective evaluation of defibrillation threshold and postshock rhythm in young ICD recipients. [PDF]

open access: yesPacing Clin Electrophysiol, 2012
Radbill AE   +6 more
europepmc   +2 more sources

Azygos Vein ICD Lead Implantation Lowers Defibrillation Threshold in a Patient with Hypertrophic Cardiomyopathy

open access: yesCardiogenetics, 2021
A 14-year-old boy with hypertrophic cardiomyopathy (HCM) diagnosed at the age of 1 year and with massive left ventricular hypertrophy suffered an episode of ventricular fibrillation during mild effort. He underwent a dual-chamber implantable cardioverter
Giovanni Quarta   +6 more
doaj   +1 more source

Computational Model for Therapy Optimization of Wearable Cardioverter Defibrillator: Shockable Rhythm Detection and Optimal Electrotherapy

open access: yesFrontiers in Physiology, 2021
Wearable cardioverter defibrillator (WCD) is a life saving, wearable, noninvasive therapeutic device that prevents fatal ventricular arrhythmic propagation that leads to sudden cardiac death (SCD).
Oishee Mazumder   +6 more
doaj   +1 more source

Do we need defibrillation threshold testing?: A pilot study [PDF]

open access: yesArchives of Biological Sciences, 2013
Defibrillation threshold testing (DFT) is a standard procedure during implantable cardioverter defibrillator (ICD) implantation, however, it is not without risks.
Kovačević-Kostić Nataša   +6 more
doaj   +1 more source

Optogenetic Stimulation Using Anion Channelrhodopsin (GtACR1) Facilitates Termination of Reentrant Arrhythmias With Low Light Energy Requirements: A Computational Study

open access: yesFrontiers in Physiology, 2021
Optogenetic defibrillation of hearts expressing light-sensitive cation channels (e.g., ChR2) has been proposed as an alternative to conventional electrotherapy.
Alexander R. Ochs   +6 more
doaj   +1 more source

Azygous vein coil lowers defibrillation threshold in patients with high defibrillation threshold [PDF]

open access: yesEuropace, 2011
Implantable cardioverter defibrillators (ICDs) reduce sudden death in patients at high risk. High defibrillation thresholds (DFTs) are not uncommon and may be the cause of failed defibrillation in patients with ICDs. Addition of a coil in the azygous vein posterior to the heart lowers the DFT in most patients by altering the electrical vector during ...
Swee-Chong, Seow   +3 more
openaire   +2 more sources

A Novel Solution for the High Defibrillation Threshold in Patients with a DF-4 Lead: Adding a High Voltage Adaptor/Splitter

open access: yesIndian Pacing and Electrophysiology Journal, 2014
A high defibrillation threshold occurs in approximately 6% of implants. The defibrillation threshold can be improved by addition of a defibrillation lead. However, the DF-4 high energy ICD header precludes the addition of a defibrillation lead.
Shmuel Inbar, MD, FACC   +1 more
doaj   +1 more source