Coronary artery compression/damage by cardiac pacing/defibrillation leads is very rare and often an unknown complication of pacemaker implantation. Here, we present the case of a 71-year-old woman with late discovery of an asymptomatic compression of the
Alex Scripcariu+2 more
doaj +1 more source
Temporal Stability and Precision of Ventricular Defibrillation Threshold Data [PDF]
Over two-hundred measurements of the minimum damped sinusoidal current and energy for transchest electrical ventricular defibrillation (ventricular defibrillation threshold) were made to determine the stability and precision of threshold data in 15 ...
Babbs, Charles F, Whistler, S J, Yim, G
core +2 more sources
Numerous T wave morphology biomarkers, which can supplement QTc assessment in long QT syndrome (LQTS), have been identified. Their diagnostic capabilities include differentiation of genotypes, identification of concealed LQTS, differentiating acquired LQTS from congenital LQTS; and determining multichannel versus hERG channel blockade.
Daniel T. Tardo+4 more
wiley +1 more source
Advantage of four-electrode over two-electrode defibrillators [PDF]
Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish the normal heart rate.
Bragard, J.+3 more
core +1 more source
Rise in chronic defibrillation thresholds in nonthoracotomy implantable defibrillator. [PDF]
BACKGROUND To establish the chronic stability of defibrillation thresholds (DFTs) in a transvenous cardioverter/defibrillator (TCD) system, we studied 37 consecutive patients with TCD systems implanted for > 6 months. METHODS AND RESULTS DFT was measured by a step-down method at ...
Ferdinand J. Venditti+3 more
openaire +3 more sources
Abstract Background The number of patients with cardiac implantable electronic devices (CIEDs) undergoing radiotherapy (RT) for cancer treatment is growing. At present, prevalence and predictors of RT‐induced CIEDs malfunctions are not defined. Methods Systematic review and meta‐analysis conducted following the PRISMA recommendations.
Vincenzo Livio Malavasi+10 more
wiley +1 more source
Is There an Effect of Amiodarone on the Defibrillation Threshold?
The interaction between amiodarone and the defibrillation threshold (DFT) is still controversial. We present a case with dilated cardiomyopathy and recurrent sustained monomorphic ventricular tachycardia who received an automatic implantable cardioverter defibrillator (AICD) while under long-term amiodarone treatment.
Turhan Akyol+4 more
openaire +4 more sources
Treatment of ineffective endocardial defibrillation with subcutaneous array: a case report
Defibrillation threshold (DFT) testing is an important part of ICD implantation. After placement of the ICD generator, a DFT test is performed to evaluate the integrity of the ICD system and to confirm a successful defibrillation safety margin. More than
Özgür Kaplan, Sabri Demircan
doaj +1 more source
Defibrillation via the Elimination of Spiral Turbulence in a Model for Ventricular Fibrillation [PDF]
Ventricular fibrillation, the major reason behind sudden cardiac death, is turbulent cardiac electrical activity in which rapid, irregular disturbances in the spatiotemporal electrical activation of the heart makes it incapable of any concerted pumping action.
arxiv +1 more source
Traumatic Tension Pneumothorax as a Cause of ICD Failure: A Case Report and Review of the Literature
Background. Tension pneumothorax can infrequently cause ventricular arrhythmias and increase the threshold of defibrillation. It should be suspected whenever there is difficulty in defibrillation for a ventricular arrhythmia. Purpose. To report a case of
Ehtesham Ul Haq, Bassam Omar
doaj +1 more source