Results 81 to 90 of about 1,216,387 (339)

Deep Neural Networks for ECG-Based Pulse Detection during Out-of-Hospital Cardiac Arrest [PDF]

open access: yes, 2019
The automatic detection of pulse during out-of-hospital cardiac arrest (OHCA) is necessary for the early recognition of the arrest and the detection of return of spontaneous circulation (end of the arrest).
Alonso, Erik   +6 more
core   +2 more sources

Animal models of cisplatin‐induced neuropathic pain

open access: yesAnimal Models and Experimental Medicine, EarlyView.
This article illustrates the modeling process of a cisplatin‐induced neuropathic pain model in rats or mice. Multiple modeling tests are required for rats or mice before, during, and after modeling. The appropriate injection method, dose, and modeling method are selected, and multiple assays are chosen for evaluation and comparison.
Ningxin Li   +9 more
wiley   +1 more source

Sonogenetics is a novel antiarrhythmic treatment [PDF]

open access: yesarXiv, 2021
Arrhythmia of the heart is a dangerous and potentially fatal condition. The current widely used treatment is the implantable cardioverter defibrillator (ICD), but it is invasive and affects the patient's quality of life. The sonogenetic treatment technique proposed here focuses transthoracic ultrasound on the heart, noninvasively stimulates endogenous ...
arxiv  

Present criteria for prophylactic ICD implantation: Insights from the EU-CERT-ICD (Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators in EUrope) project [PDF]

open access: yesJournal of Electrocardiology, 2019, 2019
BACKGROUND. The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (
arxiv   +1 more source

Сравнение энергетической эффективности дефибрилляционных импульсов на базе гипотезы гарантированной дефибрилляции [PDF]

open access: yes, 2022
The aim of this study is to compare, on the basis of the guaranteed defibrillation hypothesis, the energy efficiency of a trapezoidal defibrillation pulse with fixed rise and fall times with the main types of defibrillation pulses: truncated exponential ...
Gorbunov, B. B.   +2 more
core   +1 more source

High defibrillation threshold in patients with implantable cardioverter-defibrillator. How to solve the problem, single-center experience [PDF]

open access: yes, 2006
Standard implantable cardioverter-defibrillator with transvenous leads systems have proven to be effective in terminating ventricular tachyarrhythmias in most patients (more then 90%) with sufficient safety margin, i.e.
Kraska, Alicja   +3 more
core   +1 more source

BUN‐to‐ALB ratio as an effective predictor of 30 day mortality in ADHF patients in eastern China

open access: yesESC Heart Failure, EarlyView.
Abstract Aims The blood urea nitrogen‐to‐albumin ratio (BAR) is considered a potential indicator for assessing the poor prognosis of heart failure (HF). However, its prognostic value for Chinese patients with acute decompensated HF (ADHF) remains unclear.
Xin Huang   +8 more
wiley   +1 more source

The implanted defibrillator: relation of defibrillating lead configuration and clinical variables to defibrillation threshold

open access: yesJournal of the American College of Cardiology, 1985
Forty-two defibrillating lead systems for the automatic implantable defibrillator were implanted and tested in 41 patients. Two basic lead configurations were used: 1) spring-patch, consisting of a transvenous superior vena cava spring electrode as the anode and an apical or left lateral ventricular patch electrode (either small [13.9 cm2] or large [27.
Peter D. Chapman   +3 more
openaire   +3 more sources

Right ventricular strain predicts outcome in patients receiving sacubitril/valsartan: A sub‐analysis of DISCOVER‐ARNI

open access: yesESC Heart Failure, EarlyView.
Angiotensin receptor/Neprilysin inhibitors (ARNI) have shown to considerably improve the clinical outcome of patients with heart failure and reduced ejection fraction (HFrEF). Identifying individuals who may benefit from ARNI the most could markedly enhance patient management.
Maria Concetta Pastore   +15 more
wiley   +1 more source

Coronary vein defibrillator coil placement in patients with high defibrillation thresholds

open access: yesJournal of Arrhythmia, 2019
Background Elevated defibrillation threshold (DFT) occurs in 2%‐6% of patients undergoing implantable cardioverter defibrillator (ICD) implantation.
Moisés Rodríguez‐Mañero   +6 more
doaj   +1 more source