Results 111 to 120 of about 13,449 (262)

Electromagnetic Interference in Implantable Rhythm Devices - The Indian Scenario

open access: yesIndian Pacing and Electrophysiology Journal, 2002
Implantable rhythm device (IRD) is the generic name for the group of implantable devices used for diagnosis and treatment of cardiac arrhythmias. Devices in this category include cardiac pacemakers, implantable cardioverter defibrillators and implantable
Johnson Francis
doaj  

QT Interval Evaluation in Right Ventricular Pacing: Validation of a Novel Formula

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Abstract Background QT interval measurement in the presence of right ventricular pacing (RVP) represents a clinical challenge. We therefore aimed to derive and validate a formula for QT estimation during RVP in a large cohort of pacemaker patients. Methods and Results We prospectively enrolled 100 patients in a derivation cohort and 487 in a validation
Amr Abdin   +9 more
wiley   +1 more source

Left Ventricular wall Thickness and Decrement Evoked Potentials in Ablation of Ischemic Ventricular Tachycardia

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Preprocedural imaging can improve the success rate of ventricular tachycardia (VT) ablation. Left ventricular wall thickness (LVWT) measured by cardiac computed tomography (CT) can be used to identify infarct regions. We sought to determine whether an association exists between left ventricular wall thickness (LVWT) as obtained ...
Alwin B. P. Noordman   +4 more
wiley   +1 more source

Left Bundle Branch Area Pacing Reverts Electromechanical Window Negativity to a Similar Extent as Biventricular Pacing

open access: yesPacing and Clinical Electrophysiology, EarlyView.
BiVP = biventricular pacing; CRT = cardiac resynchronization therapy; EMW = electromechanical window; LBBAP = left bundle branch area pacing; QAoC = Time interval from the onset of the QRS complex to the center of the aortic valve closure artifact; QT = QT interval measured by tangent method.
Florien Klein   +18 more
wiley   +1 more source

Werner Irnich: Pioneer in the Development of the Dual‐Chamber Pacemaker—An Obituary

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Fifty years ago, Werner Irnich presented the concept of an optimal pacemaker capable of responding appropriately to various cardiac arrhythmias and perceptual disturbances, and intended to be used in 85% of patients. With this concept, Irnich was far ahead of his time. His proposed circuitry for AV block and atrial fibrillation, as well as his
Bernd Lemke
wiley   +1 more source

Safety and Performance of INVICTA DF4 Ventricular Defibrillation Lead: Results From APOLLO Prospective Multicenter Study

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Abstract Background Implantable cardioverter‐defibrillator (ICD) therapy relies on reliable right ventricular leads for pacing, sensing, and defibrillation. The INVICTA DF4 lead is an active‐fixation, quadripolar design intended to optimize implant workflow and long‐term safety and performance. Methods APOLLO was a prospective, multicenter, single‐arm,
Klaus K. Witte   +13 more
wiley   +1 more source

Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Magnetic resonance imaging (MRI) is a critical diagnostic tool known for its non‐invasive nature and high‐resolution imaging capabilities. However, its safety in patients with cardiac implantable electronic devices (CIEDs), particularly those with mixed‐lead systems, remains a significant clinical concern.
Ryka M. Tashakkor   +5 more
wiley   +1 more source

Implantable Microimagers

open access: yesSensors, 2008
Implantable devices such as cardiac pacemakers, drug-delivery systems, and defibrillators have had a tremendous impact on the quality of live for many disabled people.
Jun Ohta   +4 more
doaj  

First Experience With Extravascular Implantable Cardioverter‐Defibrillator Under Deep Sedation

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The Extravascular Implantable Cardioverter‐Defibrillator (EV‐ICD) utilizes a substernal lead to provide defibrillation and anti‐tachycardia pacing (ATP) while avoiding transvenous complications. General anesthesia (GA) was applied for implantation procedures in the EV‐ICD pivotal trial and is currently recommended by the ...
Nibras Soubh   +9 more
wiley   +1 more source

Impact of ICD Presence in Patients With Left Ventricular Assist Devices for End‐Stage Heart Failure

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The prognostic relevance of implantable cardioverter defibrillator (ICD) in patients with end‐stage heart failure (HF) with left ventricular assist device (LVAD) remains controversial. Objectives To evaluate the prognostic impact of ongoing use of ICD and associated complications in HF‐patients with LVAD‐implantation.
Nafilah Baridwan   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy