Results 101 to 110 of about 622,677 (326)

Comparison of strain generated in bone by "platform-switched" and "non-platform-switched" implants with straight and angulated abutments under vertical and angulated load: A finite element analysis study

open access: yesIndian Journal of Dental Research, 2013
Purpose: The aim of this study was to evaluate the microstrain exhibited by bone around immediately loaded, platform-switched, and non-platform-switched implants under vertical and angled loading using a finite element analysis (FEA) and also to evaluate
Susan Paul   +2 more
doaj   +1 more source

Targeted Muscle Reinnervation for Intuitive Prosthetic Control

open access: yesMuscle &Nerve, EarlyView.
ABSTRACT The convergence of medical and technological advances has led to a substantial expansion of therapeutic approaches for patients with limb amputations. Targeted muscle reinnervation (TMR) is one of the strategies to improve control of bionic arms and has been applied for more than two decades. Through surgical rewiring of the nerves responsible
Nitay Maile   +5 more
wiley   +1 more source

Micro-leakage at the implant-abutment interface with different tightening torques in vitro

open access: yesJournal of Applied Oral Science, 2012
OBJECTIVES: This study evaluated the microleakage at the implant/abutment interface of external hexagon (eH) implants and abutments with different amounts of bacteria and tightening torques.
João Paulo da Silva-Neto   +5 more
doaj   +1 more source

Nonthermal plasma approaches for combating implant‐associated infections: A compendious review

open access: yesVIEW, EarlyView.
Implant‐associated infections pose serious clinical challenges. Non‐thermal plasma (NTP) modifications overcome this bottleneck in distinct ways relative to traditional sterilization methods. Gas‐phase plasmas generate highly energetic species, UV radiation and reactive oxygen/nitrogen species (RONS), which alter the implant surface properties.
A. M. Trimukhe   +8 more
wiley   +1 more source

Avaliação dos valores de destorque dos parafusos de titânio em pilares personalizáveis sobre implantes com hexágono externo: um estudo in vivo [PDF]

open access: yes, 2012
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2012Avaliar os valores de diferentes técnicas de destorque dos parafusos de titânio em pilares ...
Medina, Carolina Enith Bullen
core  

Biomechanical analysis of individual all-ceramic abutments used in dental implantology [PDF]

open access: yes, 2016
Biomechanical analysis of individual all-ceramic abutments used in dental implantology The paper presents the results of finite element analysis and experimental testing under simulated physiological loading conditions on issues shaping the functional ...
Ziębowicz, B.   +4 more
core   +1 more source

The Australian and New Zealand Dental Implant Registry: Regulatory Requirements and Registry Development

open access: yesAustralian Dental Journal, EarlyView.
ABSTRACT Background The Therapeutic Goods Administration is responsible for the Regulation of manufacture and supply of all medical devices including dental implants. Medically, the patient is given a ‘Patient Implant Card’ (PIC). It is recommended to monitor the performance of devices in an implant registry.
S. Soukoulis, S. Davis, A. Goss
wiley   +1 more source

THE DENTAL TECHNICIANS PERFORMANCE STANDARDS IN MANUFACTURING THE SINGLE CROWNS ON IMPLANTS

open access: yesУкраїнський стоматологічний альманах, 2018
The most common method of dentition of included defects prosthetics using implants is manufacturing of single crowns with fixation on cement or screws. Material can be metal, ceramics, plastics and combinations thereof.
E.V. Diiev, T.V. Diieva, V.Z. Obidnyak
doaj  

Reverse torque evaluation in indexed and nonindexed abutments of Morse Taper implants in a mechanical fatigue test [PDF]

open access: yes, 2019
Background: This experimental study assessed reverse torque of indexed and nonindexed (NI) abutments in Morse Taper (MT) implants in a mechanical fatigue test.
ElimárioVenturin Ramos   +24 more
core   +1 more source

Comparison of Long vs. Short Concave Neck in One‐Piece Implants Inserted 1 mm Subcrestally: A Pre‐Clinical In Vivo Study

open access: yesClinical Oral Implants Research, EarlyView.
ABSTRACT Objectives The aim was to assess the influence of one‐piece implant concave neck height on soft‐ and hard‐tissue healing on a canine model. Material and Methods Monoblock implants with a transgingival concave neck were randomly inserted 1 mm subcrestally.
Hadi Antoun   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy