Fabrication of a Monolithic Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) Zirconia Crown Adapted to the Clasp of an Existing Removable Partial Denture. [PDF]
Takebe J.
europepmc +1 more source
Abstract Purpose This study aims to evaluate the accuracy of fit of full‐arch implant titanium frameworks fabricated from a fully digital workflow using a novel micro‐CT measurement technique. Materials and Methods A 3D‐printed model with four implant analogs was fabricated.
Amira Fouda +5 more
wiley +1 more source
Digital Removable Partial Denture Fabrication Using an Intraoral Scanner and the Altered-Cast Technique for a Patient With Free-End Partial Edentulism: A Case Report. [PDF]
Iida Y, Kameda Y, Tasaka A, Yamashita S.
europepmc +1 more source
Abstract Purpose To evaluate the shade variability and stability of interim and definitive tooth‐colored restorative materials by comparing manufacturer‐claimed shades to a universal shade guide before and after thermocycling. Materials and Methods Eight commercially available tooth‐colored restorative materials were tested, including conventional ...
Amal Alfaraj +2 more
wiley +1 more source
Repair and Reinforcement of Implant-Supported Hybrid Denture Using the Running Inlay Technique. [PDF]
Kumar NR, H S A, Ramanna PK, Raju M.
europepmc +1 more source
Effect of angulation between multi‐unit abutments on trueness of photogrammetry systems
Abstract Purpose To compare the trueness between conventional impressions (CI) and photogrammetry for full‐arch implant‐supported prosthesis and to evaluate the effect of increased inter‐abutment angulation on trueness. Materials and Methods Three edentulous reference models containing four multiunit abutment (MUA) replicas with different inter ...
Abdulelah Andejani Bin Farrah +4 more
wiley +1 more source
Fracture resistance of fixed partial dentures: the influence of restoration geometry and material in additive manufacturing. [PDF]
Kavvas-Celik E +5 more
europepmc +1 more source
Abstract Purpose To investigate the effect of surface treatment and fabrication techniques of high‐performance polymers on their shear bond strength (SBS) to grade IV titanium. Materials and Methods A total of 120 pre‐milled titanium abutments were sectioned.
Ahmet Serkan Küçükekenci +3 more
wiley +1 more source
The effect of clip material on the retention of implant retained mandibular overdenture: randomized clinical study. [PDF]
Mohamed SM, Sayed AM.
europepmc +1 more source
Abstract Purpose In metal–ceramic restorations, the substructure fabrication method and design may affect the prognosis of the prosthesis. This study evaluated and compared the fracture resistance of metal–ceramic restorations fabricated with different substructure fabrication methods using two different alloy powders and designs.
Young‐Hoon Lee +4 more
wiley +1 more source

