Results 21 to 30 of about 9,947,419 (265)
Custom abutments on tilted implants in the maxilla: A clinical report
The aim of this work is to describe a case of severe disparallelism between two implants supporting a cement-retained bridge, placed in the maxilla, employing two custom-angled abutments.
Fabrizio Di Francesco +3 more
doaj +1 more source
FACTORS AFFECTING THE ABUTMENT SCREW LOOSENING [PDF]
Aim of the study: To establish the influence of various factors upon the loosening of abutment screw. Material and Methods: The current study has analyzed the factors leading to loosening of the abutment screws implant-supported restorations.
Dimitar Kirov, Biser Stoichkov
doaj +1 more source
COMPARISON OF CEMENT AND SCREW FIXATION OF ORTHOPEDIC STRUCTURES
In dental prosthetics, every detail is important, because at this stage, not the aesthetic component is put in the first place, but the issue of engraftment of the implant.
O. S. Kosinov
doaj +1 more source
Microgap between implant and abutment can produce biological and mechanical problems such as peri-implantitis and/or fatigue failures. The aim of this study was to evaluate microgap size and fatigue behavior of external and internal connections. In both systems the torque to tighten the abutment screw of single crown abutments was 45 Ncm.
Gil Mur, Francisco Javier +3 more
openaire +4 more sources
Short dental implants in the posterior region : the effect of platform-switching and a nanorough surface on peri-implant bone loss [PDF]
Korte implantaten (10 mm lengte), waarvoor meerdere redenen bestaan. In de eerste plaats heeft een kort implantaat minder oppervlak beschikbaar voor contact tussen bot en implantaat dan een langer implantaat met eenzelfde diameter.
Telleman, Gerdien +5 more
core +3 more sources
Dental implant fracture is closely connected to the stress buildup surrounding the implant system during static loading. In areas where the cross-section of the implant rapidly changes or where the geometry of the implant system has discontinuities ...
Eser Pala +3 more
doaj +1 more source
The aim of this study was to compare the mechanical behaviors of three dental implant fixtures with different abutment connection designs. Three implant systems were studied: the control (BLX implant), test group 1 (TORX++ implant), and test group 2 (IU ...
Sung-Woon On +4 more
doaj +1 more source
Aim: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants.
Mehrak Amjadi +4 more
doaj +1 more source
Background: Dental implants have provided an alternative method of prosthetic rehabilitation with high long-term success rates. However, mechanical or biological complications may occur with implants amongst which loosening of the screw is very common. Loosening of the screw might cause misfit of implant?abutment interface and may occur due to preload ...
Dr. Prerna N Kulkarni +4 more
openaire +2 more sources
Osseointegration of zirconia implants compared with titanium : an in vivo study [PDF]
Background Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface ...
Ulrich Meyer +19 more
core +2 more sources