Results 61 to 70 of about 1,355 (266)
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm +5 more
wiley +1 more source
This study investigates thermo‐chemical processes during high‐temperature testing of two commercial MgO‐C brick grades, one containing 47.5 wt.% MgO‐C recyclate. Using ETV, DTA/TG‐MS, XRD, and SEM/EDS/EBSD, mechanisms such as carbothermal reduction of magnesia, impurity incorporation into the secondary MgO surface layer, and calcium‐rich phase ...
Alexander Schramm +6 more
wiley +1 more source
Experimental exergoeconomic assessment of a desiccant cooling system
Abstract Desiccant cooling has become a well established technology in most parts of the world, especially recently in Turkey. The increased growth of the technology was caused by the contribution of refrigerants used in conventional cooling systems to the depletion of the ozone layer.
Hurdogan, Ertac +4 more
openaire +3 more sources
Phase‐changing liquids enable untethered pneumatic actuation in soft robotics but suffer from volatility and storage challenges. This work reports a simple method to encapsulate Novec 7000 within micron‐thin alginate shells via in situ injection and ionic crosslinking.
Rayan A. M. Basodan +3 more
wiley +1 more source
Regeneration performance of liquid desiccant on the surface of a plate-type heat exchanger
Recently, there have been many studies on dehumidifiers with a low flow rate of liquid desiccant, in which a plate-type heat exchanger with internal cooling is adopted.
Tae Hyun KIM +2 more
doaj +1 more source
Experimental investigation of a novel desiccant cooling system
Desiccant based air conditioning systems are a suitable way to improve indoor air quality due to its superior humidity control. In this study, a novel desiccant based air conditioning system is designed and tested experimentally to improve the indoor air quality and reduce energy consumption.
Hurdogan, Ertac +3 more
openaire +3 more sources
Removing Oxide Layers and Retaining Oxide‐Free Steel Surfaces by Polishing in Oxygen‐Free Atmosphere
In this study, the efficacy of wet mechanical polishing under an oxygen‐free atmosphere for deoxidation and the retention of an oxide‐free steel surface are elucidated using X‐ray photoelectron spectroscopy. The methodology proved successful; however, the results were highly dependent on the preparation of the solvents used to clean the samples after ...
Friedrich Bürger +2 more
wiley +1 more source
The formation of nonmetallic inclusions (NMIs) was investigated in this study, carrying out immersion tests for 30 min at a temperature of 1600°C with liquid high‐silicon electrical steel (Si ≈ 3 mass‐%) and different MgO–C refractories. Conventional MgO–C refractories were considered, as well as MgO–C refractories containing MgO–C recyclate and ...
Lukas Neubert +6 more
wiley +1 more source
EDX elemental map of the pre‐oxidized MgO–steel cermet anode cross section after electrolysis. The development of inert anodes for aluminum electrolysis remains challenging due to the high corrosivity of cryolite‐based melts at 950°C–1000°C. This study investigates the corrosion and process behavior of a carbon‐free MgO–steel cermet anode derived from ...
Alexander Adamczyk +7 more
wiley +1 more source
Greenhouses are crucial for maintaining an ideal temperature and humidity level for plant growth; however, attaining ideal levels remains a challenge.
Fakhar Abbas +7 more
doaj +1 more source

