Results 221 to 230 of about 38,846 (279)
Desorption Electrospray Ionization Mass Spectrometry Imaging Techniques Depict a Reprogramming of Energy and Purine Metabolism in the Core Brain Regions of Chronic Social Defeat Stress Mice. [PDF]
Song Y, Xiao F, Aa J, Wang G.
europepmc +1 more source
Transmission mode desorption electrospray ionization [PDF]
A new mode of operation for desorption electrospray ionization (DESI) analysis of liquids or solid residues from evaporated solvents is presented. Unlike traditional DESI, the electrospray is not deflected off of a surface but instead is transmitted through a sampling mesh at a 0 degrees angle between the electrospray tip, sample mesh, and capillary ...
Jennifer S Brodbelt
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Journal of the American Society for Mass Spectrometry, 2012
Spray desorption collection (SDC) and reflective electrospray ionization (RESI) were used to independently study the desorption and ionization processes that together comprise desorption electrospray ionization (DESI). Both processes depend on several instrumental parameters, including the nebulizing gas flow rate, applied potential, and source ...
Shashank Jain, André R Venter
exaly +3 more sources
Spray desorption collection (SDC) and reflective electrospray ionization (RESI) were used to independently study the desorption and ionization processes that together comprise desorption electrospray ionization (DESI). Both processes depend on several instrumental parameters, including the nebulizing gas flow rate, applied potential, and source ...
Shashank Jain, André R Venter
exaly +3 more sources
Salt tolerance of desorption electrospray ionization (DESI) [PDF]
The salt tolerance of desorption electrospray ionization (DESI) was systematically investigated by examining three different drug mixtures in the presence of 0, 0.2, 2, 5, 10, and 20% NaCl:KCl (1:1) from different surfaces. At physiological salt concentrations, the individual drugs in each mixture were observed in each experiment.
Ayanna U Jackson +2 more
exaly +3 more sources
Redox transformations in desorption electrospray ionization
International Journal of Mass Spectrometry, 2009Abstract Redox changes occur in some circumstances when organic compounds are analyzed by desorption electrospray ionization mass spectrometry (DESI-MS). However, these processes are limited in scope and the data presented here suggest that there are only limited analogies between the redox behavior in DESI and the well-known solution-phase ...
Mario Benassi +2 more
exaly +2 more sources

