IEEE Transactions on Terahertz Science and Technology, 2012
An experimental method is presented for characterizing the full optical behavior of few-mode power detectors. The technique involves illuminating the detector with a pair of coherent sources. When the phase of one source is rotated relative to the other, the detector output displays a fringe.
Christopher N. Thomas +1 more
openaire +1 more source
An experimental method is presented for characterizing the full optical behavior of few-mode power detectors. The technique involves illuminating the detector with a pair of coherent sources. When the phase of one source is rotated relative to the other, the detector output displays a fringe.
Christopher N. Thomas +1 more
openaire +1 more source
Medical Physics, 2014
Purpose:Lung SBRT is being used by an increasing number of clinics, including our center which recently treated its first patient. In order to validate this technique, the 3D dose distribution of the SBRT plan was measured using a previously developed 3D detector based on plenoptic camera and plastic scintillator technology.
M Goulet +5 more
openaire +1 more source
Purpose:Lung SBRT is being used by an increasing number of clinics, including our center which recently treated its first patient. In order to validate this technique, the 3D dose distribution of the SBRT plan was measured using a previously developed 3D detector based on plenoptic camera and plastic scintillator technology.
M Goulet +5 more
openaire +1 more source
Applied Radiation and Isotopes, 2016
Response function of a widely used 3in×3in NaI(Tl) detector is constructed to correct the observed pulse height distribution. A 10×10 inverse matrix is constructed using 7 mono-energetic gamma sources ((57)Co, (203)Hg, (133)Ba, (22)Na, (137)Cs, (54)Mn and (65)Zn) which are evenly spaced in energy scale to unscramble the observed pulse height ...
K U, Kiran +3 more
openaire +2 more sources
Response function of a widely used 3in×3in NaI(Tl) detector is constructed to correct the observed pulse height distribution. A 10×10 inverse matrix is constructed using 7 mono-energetic gamma sources ((57)Co, (203)Hg, (133)Ba, (22)Na, (137)Cs, (54)Mn and (65)Zn) which are evenly spaced in energy scale to unscramble the observed pulse height ...
K U, Kiran +3 more
openaire +2 more sources
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998
Abstract A novel tank reactor equipped with t otal electron yield (TEY) detectors was designed and constructed for in situ X-ray absorption spectroscopy (XAS) investigations in the soft X-ray range (250 eV ⩽ by ⩽ 1000 eV) under elevated pressures (up to 20 mbar) and sample temperatures (up to 1000 K). This allows, for the first time, XAS studies in
Knop-Gericke, A. +3 more
openaire +2 more sources
Abstract A novel tank reactor equipped with t otal electron yield (TEY) detectors was designed and constructed for in situ X-ray absorption spectroscopy (XAS) investigations in the soft X-ray range (250 eV ⩽ by ⩽ 1000 eV) under elevated pressures (up to 20 mbar) and sample temperatures (up to 1000 K). This allows, for the first time, XAS studies in
Knop-Gericke, A. +3 more
openaire +2 more sources
Review of Scientific Instruments
The double torsion pendulum, which can provide quasi-free fall motion modes with two degrees of freedom simultaneously, can be used to evaluate the crosstalk effect of gravitational reference sensors (GRSs) in space-based gravitational wave detection on the ground.
Yu-You Duan +6 more
openaire +2 more sources
The double torsion pendulum, which can provide quasi-free fall motion modes with two degrees of freedom simultaneously, can be used to evaluate the crosstalk effect of gravitational reference sensors (GRSs) in space-based gravitational wave detection on the ground.
Yu-You Duan +6 more
openaire +2 more sources
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin, 1999
Experimental and clinical evaluation of a digital flat-panel X-ray system based on cesium iodide (CsI) and amorphous silicon (a-Si).Performance of a prototype detector was compared with conventional screen-film radiography (SFR) using several phantom studies. Foreign bodies, fractures, osteolyses, and pulmonary lesions were analyzed.
M, Strotzer +4 more
openaire +1 more source
Experimental and clinical evaluation of a digital flat-panel X-ray system based on cesium iodide (CsI) and amorphous silicon (a-Si).Performance of a prototype detector was compared with conventional screen-film radiography (SFR) using several phantom studies. Foreign bodies, fractures, osteolyses, and pulmonary lesions were analyzed.
M, Strotzer +4 more
openaire +1 more source
2019
Evaluation of the annual average radon concentrations in dwellings and workplaces, as required by the recent international regulations, is commonly performed using techniques based on passive devices containing nuclear track detectors and tracks read-out systems.
Venoso G. +4 more
openaire +1 more source
Evaluation of the annual average radon concentrations in dwellings and workplaces, as required by the recent international regulations, is commonly performed using techniques based on passive devices containing nuclear track detectors and tracks read-out systems.
Venoso G. +4 more
openaire +1 more source