Results 21 to 30 of about 10,066 (215)
This paper investigates a doubly-fed wind turbine generation system (DFIG) where the rotor-side control parameters have a significant impact on the effectiveness of the DFIG due to the adoption of its inner-loop current and outer-loop power control ...
Tao Cheng +3 more
doaj +1 more source
Influence of Static Var Generator on High Frequency Oscillation of Doubly-Fed Wind Farm
The connection of static var generator (SVG) in doubly-fed wind farms can easily cause high frequency oscillation in the system, which seriously threatens the safe and stable operation of wind farms.
Linlin WU +5 more
doaj +1 more source
The impact of wind generators on a Powe system's transient stability [PDF]
This thesis discusses the investigations carried out on the different types of wind generators and how these would affect the transient stability of a hypothetical power network as presented in this report.
Khomari, Moloantoa
core +1 more source
The main purpose of this paper is allowing doubly fed induction generator wind farms (DFIG), which are connected to power system, to effectively participate in feeding electrical loads.
Ahmed Elkasem +3 more
doaj +1 more source
The doubly fed induction generator (DFIG) usually experiences high rotor current and DC capacitor link voltage spikes during system fault events. In this paper, a novel data‐driven approach is proposed to enhance DFIG performance under fault scenarios ...
Wei Gao +7 more
doaj +1 more source
ROBUST SECOND ORDER SLIDING MODE CONTROL OF DOUBLY-FED INDUCTION GENERATOR FOR WIND ENERGY CONVERSION SYSTEM [PDF]
This paper presents a robust nonlinear control strategy based on second-order continuous sliding mode control called SuperTwisting Sliding Mode Control (ST-SMC) strategy of a doubly-fed induction generator (DFIG) integrated into a Wind Energy Conversion
Youcef DJERIRI
doaj +1 more source
According to modern grid regulations, doubly fed induction generator (DFIG) needs to operate without losing synchronism during grid faults. But, severe fault leads to rise in stator and rotor current to a higher value and generator will get damaged ...
D.V.N. Ananth, G.V. Nagesh Kumar
doaj +1 more source
This paper aims to explore a viable monitoring and management of active and reactive powers for a large-scale wind farm based on Doubly-Fed Induction Generators (DFIG) considering the voltage Fault-Ride-Through capability (FRT), especially Low-Voltage ...
Hammadi Laghridat +2 more
doaj +1 more source
Backstepping approach applied to the DFIG-WECS [PDF]
The growing need for energy in the world and the depletion of classical energy resources (fuels) have led researchers to develop new means of producing abundant and inexhaustible energies called “renewable energies”. In this context, we propose the study of a Wind Energy Conversion System (WECS) driven by a Doubly Fed Induction Generator (DFIG).
Hala Alami Aroussi +2 more
openaire +1 more source
An Accurate Forced Oscillation Location and Participation Assessment Method for DFIG Wind Turbine
With the integration of wind energy, the widely used doubly fed induction generator wind turbines (DFIG-WT) could induce Power System forced oscillations (FOs), which threaten the safety of power grid.
Jiaxing Lei +4 more
doaj +1 more source

