Results 41 to 50 of about 29,352 (225)

Quantitative Control Approach for Wind Turbine Generators to Provide Fast Frequency Response with Guarantee of Rotor Security

open access: yes, 2017
Wind generation is expected to reach substantially higher levels of penetration in the near future. With the converter interface, the rotor inertia of doubly-fed induction generator (DFIG) based wind turbine generator is effectively decoupled from the ...
Tomsovic, Kevin, Wang, Siqi
core   +1 more source

Method of DFIG Cooperating with SVG to Suppress Low-Frequency Oscillation in Power Systems

open access: yesZhongguo dianli, 2020
With the increasing penetration of wind power, when the power system is insufficiently damped, low-frequency oscillations are likely to occur. Doubly fed induction generation (DFIG) can decouple the control of active and reactive power, which helps ...
Lei YANG   +7 more
doaj   +1 more source

Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through [PDF]

open access: yes, 2014
This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ...
Ackermann   +7 more
core   +2 more sources

Heteroclinic connections between periodic orbits and resonance transitions in celestial mechanics [PDF]

open access: yes, 2000
In this paper we apply dynamical systems techniques to the problem of heteroclinic connections and resonance transitions in the planar circular restricted three-body problem.
Koon, Wang Sang   +3 more
core   +3 more sources

Backstepping approach applied to the DFIG-WECS [PDF]

open access: yesInternational Meeting on Advanced Technologies in Energy and Electrical Engineering, 2020
The growing need for energy in the world and the depletion of classical energy resources (fuels) have led researchers to develop new means of producing abundant and inexhaustible energies called “renewable energies”. In this context, we propose the study of a Wind Energy Conversion System (WECS) driven by a Doubly Fed Induction Generator (DFIG).
Hala Alami Aroussi   +2 more
openaire   +1 more source

Lyapunov-Based Robust Power Controllers for a Doubly Fed Induction Generator

open access: yesIranian Journal of Electrical and Electronic Engineering, 2020
In this work, a robust nonlinear control technique of a doubly fed induction generator (DFIG) intended for wind energy systems has been proposed. The principal idea in this article is to decouple the active and reactive power of the DFIG with high ...
Y. Djeriri
doaj  

Analysis of Frequency Regulation Capability of Doubly Fed Induction Generator and Supercapacitor Energy Storage Based on Dynamic Power Flow

open access: yesEnergies, 2023
The grid-integrated doubly fed induction generator (DFIG) is required to participate in the frequency regulation of the power system. The supercapacitor energy storage (SES) is capable of enhancing the frequency regulation capability of the DFIG in a ...
Tingting Sun   +3 more
doaj   +1 more source

Empirical Physics‐Based Normal Behavior Modeling of Drive Train Temperatures With High‐Resolution Wind Turbine Operating Data

open access: yesWind Energy, EarlyView.
ABSTRACT The installed wind energy capacity increases every year. However, operation and maintenance costs still make up a considerable portion of the levelized costs of electricity. This costs can be greatly reduced by the application of suitable early fault detection methods. The supervisory control and data acquisition system of wind turbines is one
Timo Lichtenstein   +2 more
wiley   +1 more source

Impedance characteristics of DFIGs considering the impacts of DFIG numbers and its application on SSR analysis

open access: yesIOP Conference Series: Materials Science and Engineering, 2017
Sub-synchronous resonance (SSR) occurred in the power system with both Doubly Fed Induction Generators (DFIGs) and series-compensated lines. There have been several papers focusing on the analysis of such SSR phenomenon. To the authors' knowledge, the impacts of DFIG numbers are seldom considered in existing papers.
J J You   +5 more
openaire   +1 more source

Techno-economic comparison of operational aspects for direct drive and gearbox-driven wind turbines [PDF]

open access: yes, 2010
The majority of wind turbines currently in operation have the conventional Danish concept design-that is, the three-bladed rotor of such turbines is indirectly coupled with an electrical generator via a gearbox.
Ault, G.W., McMillan, David
core   +1 more source

Home - About - Disclaimer - Privacy