Results 71 to 80 of about 5,364,392 (254)

A Dual‐Modal Wearable PPG Smartwatch with AI‐Enhanced Correction for High‐Accuracy and Continuous AF Burden Assessment

open access: yesAdvanced Science, EarlyView.
ABSTRACT Atrial fibrillation (AF) increases the risk of stroke and heart failure, yet accurate quantification of AF burden in daily life remains difficult. Although smartwatch photoplethysmography (PPG) supports continuous monitoring, complex rhythms and signal noise can impair burden estimation.
Song Zuo   +27 more
wiley   +1 more source

EFFICACY OF CORMOBID OCTEOARTHROSIS WITH ARTERIAL HYPERTENSION CONTROL CONSIDERING THE TYPES OF ORTHOSTATIC REACTIONS AND CARCADIAN PROFILES OF ARTERIAL PRESSURE

open access: yesJournal of V. N. Karazin Kharkiv National University: Series Medicine, 2013
Clinical peculiarities, heart rate variability and effectiveness of comorbid osteoarthrosis with arterial hy-pertension control considering the types of orthostatic reactions and circadian profiles of blood pressure were established.
I. V. Soldatenko   +3 more
doaj  

Soft, Multi‐Wavelength Photoplethysmography Enables Reliable Neonatal Blood Pressure Monitoring Via Error Stratification

open access: yesAdvanced Science, EarlyView.
A soft hybrid multi‐wavelength PPG wearable acquires neonatal signals. Synchronized PPG and invasive ABP data are segmented into fixed windows. A 1D‐EfficientNet model predicts segment‐level SBP and DBP. Model performance is examined with retrospective subgroup analysis across acquisition conditions.
Wenqi Shi   +12 more
wiley   +1 more source

Correction ofvitamin D deficiency/insufficiency and assessment of 24-hour blood pressure parameters in perimenopausal women with arterial hypertension

open access: yesPediatria i Medycyna Rodzinna, 2014
Both arterial hypertension and vitamin D deficiency are highly prevalent in the general population. Aim of the study was to assess blood pressure and its dynamics in 24-hour ambulatory blood pressure monitoring (ABPM) while correcting the vitamin D ...
Ludmiła Walerjewna Jankowska   +1 more
doaj   +1 more source

A Novel Pak1 Activator Ameliorates ER Stress for HFpEF Therapy

open access: yesAdvanced Science, EarlyView.
Chronic metabolic stress is a major contributor to HFpEF progression. Under prolonged metabolic stress, Pak1 activity becomes impaired, contributing to disrupted ER proteostasis, cardiomyocyte apoptosis, fibrosis, and diastolic dysfunction. Mechanistically, Pak1 overexpression activates the ERK1/2–MNK1–eIF4E signaling axis, promotes translational ...
Honglin Xu   +17 more
wiley   +1 more source

Printable Piezoresistive Hybrid Hydrogels Based on 2D MoS2 for Flexible Pulse Sensing

open access: yesAdvanced Science, EarlyView.
Hybrid 1T‐MoS2‐based hydrogels are engineered through UV curing and 3D printing to achieve tunable electromechanical properties for wearable sensing. These soft architectures enhance mechanical stability and reproducible piezoresistive responses within the physiological pressure range.
Jenny Flores   +18 more
wiley   +1 more source

Metabolic Memory in Cardiovascular Disease: Encoding, Propagation, and Therapeutic Targeting

open access: yesAdvanced Science, EarlyView.
Cardiovascular risk often persists after metabolic abnormalities are corrected. This conceptual Review frames such persistence as metabolic memory, encoded through a narrowing therapeutic window from reversible marks to irreversible damage, with continuous input from peripheral organs.
Cheng Cheng   +12 more
wiley   +1 more source

Is nurse-measured blood pressure a valid substitute for ambulatory blood pressure monitoring?

open access: yes, 2000
BACKGROUND: Because ambulatory blood pressure monitoring (ABPM) is not available everywhere, the objective of the study was to determine whether nurse-measured blood pressure could be an acceptable substitute to ABPM.
Gerc, V.   +3 more
core   +1 more source

Increased Disarray of Extracellular Matrix Collagen‐I Fiber Network and Compromised Biomechanics in Aortae From Marfan‐Syndrome Mice Assessed Through Combined Opto‐Biomechatronics

open access: yesAdvanced Science, EarlyView.
Combined structure‐function assessment in aortic rings from Marfan mice using MechaMorph Opto‐Biomechatronics technology relates increased elasticity (stiffness) and dynamic viscosity and less ordered extracellular matrix 3D‐structure (collagen) as potential causes for impaired Windkessel function and compromised haemodynamics in Marfan's syndrome ...
Dominik Schneidereit   +10 more
wiley   +1 more source

Effects of crossed leg on blood pressure

open access: yes, 2004
It is known that many factors influence an individual's blood pressure measurement. However, guidelines for accurately measuring blood pressure inconsistently specify that the patient should keep feet flat on the floor. The purpose of this study was

core   +1 more source

Home - About - Disclaimer - Privacy