Results 211 to 220 of about 28,921 (265)
Some of the next articles are maybe not open access.

Some Problems in Dielectric-Loss Measurements

Transactions of the American Institute of Electrical Engineers, 1929
The measurement of dielectric loss in high-voltage cables presents many problems that are not obvious until such measurements have actually been attempted and the results checked and analyzed. Some of these problems are not simple, and their solution is obtained only after considerable effort and research.
C. L. Dawes   +2 more
openaire   +1 more source

Technique for Measuring Dielectric Loss Tangent

Review of Scientific Instruments, 1966
Dielectric loss tangent measurement in pyroelectric materials for EM radiation detectors and heat transfer ...
Glenn A. Burdick, Travis G. Hickman
openaire   +1 more source

Measurement of Ultralow Losses in Dielectric Mirrors

Optical Interference Coatings, 1992
Characterization of low loss mirrors by measurements of cavity decay time and of cavity finesse are reported around 850 nm. The lowest observed loss is 1.6 ppm (transmission and absorption and scatter), corresponding to a reflectivity of 0.9999984.
R. Lalezari   +3 more
openaire   +1 more source

Dielectric loss measurements on raw materials

American Journal of Physics, 1980
This paper describes a relatively simple experiment which can be performed by undergraduate students to study the dielectric properties of materials. Values of the dielectric loss tangent can be determined at low frequencies from Lissajous figures formed on an oscilloscope. Sample results for mineral rock specimens are presented.
openaire   +1 more source

Measurement of the permittivity and loss tangent of dielectric sheets

Microwave and Optical Technology Letters, 1997
A previously introduced resonant measurement technique is extended to include dielectric sheets. The technique is not limited by the sheet's thickness or dielectric constant because it involves a full-wave analysis of the fixture. A method to account for conduction loss due to the surface resistance of the metal walls of the fixture is presented ...
William R. Humbert, Waymond R. Scott
openaire   +1 more source

A Microwave Dielectric Loss Measuring Technique

Journal of Applied Physics, 1946
Dielectric loss is measured by Q determinations of a resonator partially filled with the sample. Double sample technique is used to eliminate dominant spurious losses. Metal loss is reduced by confining field mostly to sample. Detuning for Q determination is accomplished by large movement of small rod. Detuning is calculated by action theorem.
openaire   +1 more source

Open resonators for low dielectric loss measurements

Technical Physics, 2002
Open resonators are studied based on the scattering theory. In particular, a theory of open resonators with a dielectric plate is constructed. This theory is used to develop a technique for measuring small dielectric loss. Measurements of the loss tangent in diamond plates show that the volume absorption in the best samples is ≈7×10−6 in the high ...
S. N. Vlasov   +3 more
openaire   +1 more source

The calorimetric measurement of low temperature dielectric loss

Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1975, 1975
Most dielectric loss measurements are made by using a capacitance bridge. Bridge methods however require standard capacitors. These capacitors have dielectric loss tangents of about 10−5 and loss tangents smaller than this cannot easily be measured with bridge techniques.
Christopher N. King, Richard A. Thomas
openaire   +1 more source

Dielectric Loss Measurements Parallel to Laminations

Journal of Applied Physics, 1937
Laminated material is often used as insulation in an electrical device in such a way that a large component of the dielectric field passes through it parallel to its laminations. In present test methods dielectric loss measurements are made on such material with the dielectric field passing through it perpendicular to its lamination. It is evident that
openaire   +1 more source

Open resonator for measuring high-losses dielectric

International Journal of Infrared and Millimeter Waves, 1996
The three-mirror open resonator (OR) with the prism of total-internal-reflection (TIR) for measuring dielectric constants of high-losses dielectrics is presented. The calculations of the resonator characteristics in approximation of wave beams have been carried out.
Nina A. Popenko   +2 more
openaire   +1 more source