Results 11 to 20 of about 54,450 (268)
Transition Structure Between Coaxial Cable and Dielectric Rod Waveguide in Microwave Frequency
The dielectric waveguide in THz and millimeter circuit is widely researched. However, it is rarely researched in a microwave frequency. In this article, a dielectric rod waveguide (DRW) is proposed with low transmission loss in microwave frequency.
Yin Li +3 more
doaj +1 more source
An In2O3/ITO thin film thermocouple was prepared via screen printing. Glass additives were added to improve the sintering process and to increase the density of the In2O3/ITO films. The surface and cross-sectional images indicate that both the grain size
Yantao Liu +9 more
doaj +1 more source
In2O3/ITO thin film thermocouples for high temperature measurement (up to 1250 °C) were prepared by radio frequency magnetron sputtering method with different annealing temperatures from 1100 °C to 1250 °C. The changes with microstructure characteristics
Yantao Liu +8 more
doaj +1 more source
Introduction. Measurements on alternating current of dielectric absorption parameters – capacitance and dielectric loss tangent tgδ allow us to evaluate the quality of insulation of cables, electrical machines, transformers, etc., both at the ...
G. V. Bezprozvannych, I. A. Kostiukov
doaj +1 more source
A novel and efficient enzymatic glucose sensor was fabricated based on Fe3O4 magnetic nanoparticles (Fe3O4MNPs)-modified urchin-like ZnO nanoflowers (ZnONFs). ZnONFs were hydrothermally synthesizing on a flexible PET substrate.
Qi Mao +7 more
doaj +1 more source
W-band Silicon dielectric measurement
In this paper, a free space based method for measurement of silicon dielectric constant is presented at W band frequencies. The dielectric constant of silicon is calculated using measured phase information of the transmitted signal (S21) through Silicon sheet of 500um thickness.
Seyyedesfahlan, Mirmehdi +2 more
openaire +1 more source
The dielectric properties of biological tissues are typically measured using the open-ended coaxial probe technique, which is based on the assumption that the tissue sample is homogeneous.
Alessandra La Gioia +2 more
doaj +1 more source
In this paper, a very high sensitivity microwave-based planar microfluidic sensor is presented. Sensitivity enhancement is achieved and described theoretically and experimentally by eliminating any extra parasitic capacitance not contributing to the ...
Haneen Abdelwahab +4 more
doaj +1 more source
In-Situ Moisture Assessment in External Walls of Historic Building using Non-Destructive Methods
In-situ measurements of a case study building located in Riga old town near the river Daugava has been carried out in this work. Performed measurements are moisture level of historic masonry, and interstitial monitoring of temperature and relative ...
Freimanis Ritvars +3 more
doaj +1 more source
Design and Calibration of a Low-Cost SDI-12 Soil Moisture Sensor
Water is the main limiting factor in agricultural production as well as a scarce resource that needs to be optimized. The measurement of soil water with sensors is an efficient way for optimal irrigation management.
Juan D. González-Teruel +5 more
doaj +1 more source

