Results 71 to 80 of about 54,450 (268)

Dielectric Properties Determination of a Stratified Medium [PDF]

open access: yesRadioengineering, 2015
The method of detection of variation in dielectric properties of a material covered with another material, which requires nondestructive measurement, has numerous applications and the accurate measurement system is desirable.
P. Yoiyod, M. Krairiksh
doaj  

Rational Fine‐Tuning of MOF Pore Metrics: Enhanced SO2 Capture and Sensing with Optimal Multi‐Site Interactions

open access: yesAdvanced Functional Materials, EarlyView.
A pore tuning strategy to amplify the multi‐site MOF‐SO2 interactions is proposed to achieve an enhanced trace SO2 capture and chemiresistive sensing in highly stable isostructural DMOFs by annelating benzene rings. This work provides a facile strategy to achieve tailor‐made stable MOF materials for specific multifunctional applications.
Shanghua Xing   +9 more
wiley   +1 more source

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

Dielectric Characterization of In Vivo Abdominal and Thoracic Tissues in the 0.5–26.5 GHz Frequency Band for Wireless Body Area Networks

open access: yesIEEE Access, 2019
The dielectric properties of biological tissues are of utmost importance in the development of wireless body area networks (WBANs), especially for implanted devices.
Alejandro Fornes-Leal   +6 more
doaj   +1 more source

Printed Integrated Logic Circuits Based on Chitosan‐Gated Organic Transistors for Future Edible Systems

open access: yesAdvanced Functional Materials, EarlyView.
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco   +8 more
wiley   +1 more source

Modulating Two‐Photon Absorption in a Pyrene‐Based MOF Series: An In‐Depth Investigation of Structure–Property Relationships

open access: yesAdvanced Functional Materials, EarlyView.
This study investigates H4TBAPy‐based metal–organic frameworks (MOFs) ‐ NU‐1000, NU‐901, SrTBAPy, and BaTBAPy ‐ for multiphoton absorption (MPA) performance. It observes topology‐dependent variations in the 2PA cross‐section, with BaTBAPy exhibiting the highest activity.
Simon N. Deger   +10 more
wiley   +1 more source

Attenuation measurement of dielectric waveguide

open access: yesElectronics Letters, 1974
Measurements have been made of the attenuation coefficient of square-cross-section dielectric waveguide by a transmission technique over the frequency range 9.0?18.0 GHz. These measurements have been shown to agree with theoretical predictions made by Ozkan and Schlosser and Unger.
R.J. Collier, P.D. White
openaire   +1 more source

Laser‐Induced Graphene from Waste Almond Shells

open access: yesAdvanced Functional Materials, EarlyView.
Almond shells, an abundant agricultural by‐product, are repurposed to create a fully bioderived almond shell/chitosan composite (ASC) degradable in soil. ASC is converted into laser‐induced graphene (LIG) by laser scribing and proposed as a substrate for transient electronics.
Yulia Steksova   +9 more
wiley   +1 more source

Highly Sensitive Electrochemical Biosensor Based on Hairy Particles with Controllable High Enzyme Loading and Activity

open access: yesAdvanced Functional Materials, EarlyView.
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy