Results 251 to 260 of about 317,017 (264)
Some of the next articles are maybe not open access.
IEEE Transactions on Electron Devices, 1988
A tunneling injection mechanism into the channel of a modulation doping field effect transistor is discussed. In the presaturation regime of the drain current, the source current exhibits negative differential resistance as a result of the charge control by the gate field in the channel.
J.-P. Leburton, J. Kolodzey
openaire +1 more source
A tunneling injection mechanism into the channel of a modulation doping field effect transistor is discussed. In the presaturation regime of the drain current, the source current exhibits negative differential resistance as a result of the charge control by the gate field in the channel.
J.-P. Leburton, J. Kolodzey
openaire +1 more source
Journal of Pharmaceutical Sciences, 1974
The drug release pattern of micronized ethynodiol diacetate from silicone devices was thoroughly investigated in polyethylene glycol-containing elution media with a wide range of solubility and partition properties. When high drug solubility was maintained, the drug release pattern followed a Q - t1/2 relationship (matrix controlled). Under this matrix-
Y W, Chien, H J, Lambert
openaire +2 more sources
The drug release pattern of micronized ethynodiol diacetate from silicone devices was thoroughly investigated in polyethylene glycol-containing elution media with a wide range of solubility and partition properties. When high drug solubility was maintained, the drug release pattern followed a Q - t1/2 relationship (matrix controlled). Under this matrix-
Y W, Chien, H J, Lambert
openaire +2 more sources
The Journal of Heart and Lung Transplantation, 2016
LVAD+Pulsatility immediately post-OHT, with partial attenuation of this difference by 6 months, and normalization by 12 months post-OHT. Conclusion: Aortic stiffness is markedly increased immediately post-OHT among patients bridged with CF-LVADs, with attenuation of this increased stiffness over the first year after transplant.
J.M. Schaenman +10 more
openaire +1 more source
LVAD+Pulsatility immediately post-OHT, with partial attenuation of this difference by 6 months, and normalization by 12 months post-OHT. Conclusion: Aortic stiffness is markedly increased immediately post-OHT among patients bridged with CF-LVADs, with attenuation of this increased stiffness over the first year after transplant.
J.M. Schaenman +10 more
openaire +1 more source
International Journal of Quantum Chemistry, 2018
AbstractThe electronic transport properties of the molecular device based on double‐cage fluorinated fullerene C20F18(NH)2C20F18 were studied theoretically. The results show that the device exhibits two negative differential resistance (NDR) peaks in its I‐V curve.
Jiang‐yu Bian +2 more
openaire +1 more source
AbstractThe electronic transport properties of the molecular device based on double‐cage fluorinated fullerene C20F18(NH)2C20F18 were studied theoretically. The results show that the device exhibits two negative differential resistance (NDR) peaks in its I‐V curve.
Jiang‐yu Bian +2 more
openaire +1 more source
Small
AbstractCells perceive external and internally generated forces of different kinds, significantly impacting their cellular biology. In the relatively nascent field of mechanobiology, the impact of such forces is studied and further utilized to broaden the knowledge of cellular developmental pathways, disease progression, tissue engineering, and ...
Soumyadeep Basak, Gopinath Packirisamy
openaire +2 more sources
AbstractCells perceive external and internally generated forces of different kinds, significantly impacting their cellular biology. In the relatively nascent field of mechanobiology, the impact of such forces is studied and further utilized to broaden the knowledge of cellular developmental pathways, disease progression, tissue engineering, and ...
Soumyadeep Basak, Gopinath Packirisamy
openaire +2 more sources
Applied Mechanics and Materials, 2011
New rotary to linear conversion mechanism named "reverse-type differential rotary to linear conversion mechanism (RDRLCM)" was invented for simultaneous achievement of large load capacity and precise displacement control, for compression test devices and press forming machines. The new mechanism was developed and incorporated as loading systems into an
openaire +1 more source
New rotary to linear conversion mechanism named "reverse-type differential rotary to linear conversion mechanism (RDRLCM)" was invented for simultaneous achievement of large load capacity and precise displacement control, for compression test devices and press forming machines. The new mechanism was developed and incorporated as loading systems into an
openaire +1 more source
Identification of Multiple Failure Mechanisms for Device Reliability Using Differential Evolution
IEEE Transactions on Device and Materials Reliability, 2023Uttara Chakraborty +3 more
openaire +1 more source
Development of a Spherical Tether Handling Device with a Coupled Differential Mechanism
The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2016Tomoya ICHIMURA +4 more
openaire +1 more source
The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec), 2020
Hayato IWATA +2 more
openaire +1 more source
Hayato IWATA +2 more
openaire +1 more source

