Results 11 to 20 of about 2,378 (215)
The uses of high-temperature superconducting (HTS) cables pose a challenge of power system protection since the impedance of the HTS cable is varied during fault conditions. The protection systems should be designed properly to ensure the reliability and
Thai-Thanh Nguyen +3 more
doaj +1 more source
A Distribution Line Protection Scheme for Network with Distributed Generation
Installation of distributed generations (DGs) can cause performance degradation of distribution lines protection. Therefore, the objective of this paper is to propose a protection scheme that can be a solution for this protection line degradation..
Adrianti Adrianti +2 more
doaj +1 more source
Optimal coordination and settings of directional overcurrent relays (DOCRs) are crucial task to ensure reliable and effective protection in power system networks. The settings of DOCRs are plug setting current (PSC) and time multiplier setting (TMS). The
Suzana Pil Ramli +4 more
doaj +1 more source
An Adaptive Overcurrent Coordination Scheme to Improve Relay Sensitivity and Overcome Drawbacks due to Distributed Generation in Smart Grids [PDF]
Distributed Generation (DG) brought new challenges for protection engineers since standard relay settings of traditional system may no longer function properly under increasing presence of DG.
Conde, Arturo +3 more
core +1 more source
Microgrid Protection through Adaptive Overcurrent Relay Coordination
The inclusion of distributed energy resources (DER) in Microgrids (MGs) comes at the expense of increased changes in current direction and magnitude.
Haneen Bawayan, Mohamed Younis
doaj +1 more source
As the development of renewable distributed generations (DGs) is growing rapidly, the autonomous self-healing microgrid had emerged as an effective solution for integrating renewable DGs in the distribution networks.
Kheng Heong Oon +4 more
doaj +1 more source
Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault [PDF]
This paper presents the impact of GTO Controlled Series Capacitor (GCSC) parameters on the Inverse Definite Minimum Time (IDMT) Directional Overcurrent Relay (DOCR) based on the International Electrotechnical Commission (IEC) standards. The DOCR
Zellagui Mohamed +3 more
doaj +1 more source
Distance Protection for Microgrids in Distribution System [PDF]
Owing to the increasing penetration of distributed generation, there are some challenges for the conventional protection in distribution system. Bidirectional power flow and variable fault current because of the various operation modes may lead to the ...
Guerrero, Josep M. +3 more
core +2 more sources
An Adaptive Overcurrent Coordination Scheme Withstanding Active Network Operations
This paper aims to present a centralized adaptive protection scheme (APS) for the directional overcurrent relays (DOCRs) considering system dynamics such as load demand variations, topology changes and DGs to mitigate the above-mentioned effects.
Arturo Conde, Meng Yen Shih
doaj +1 more source
Evaluation of a Local Fault Detection Algorithm for HVDC Systems [PDF]
A great increase in the amount of energy generated from clean and renewable sources integrated in the electric power system is expected worldwide in the coming years.
Eguia Lopez, P. +4 more
core +2 more sources