Results 241 to 250 of about 4,504,709 (295)
Some of the next articles are maybe not open access.
Temperature-sensitive repetitive discharges in paramyotonia congenita
Muscle & Nerve, 1997A 47-year-old female with paramyotonia congenita was studied with electromyography and showed minimal myotonic discharges but prominent repetitive discharges in hand muscles at room temperature. With cooling the hand, the repetitive discharges ceased as the myotonic potentials became prominent. With exercise and further cooling, the myotonic discharges
M D, Weiss, R F, Mayer
openaire +2 more sources
The determination of the discharge channel axis temperature as a function of discharge time
Journal of Quantitative Spectroscopy and Radiative Transfer, 1969Abstract The normalized intensity values as functions of channel-axis temperature have been calculated on an electronic computer for Ar I 3554.31, Ar II 3576.61, Ar III 3503.58, Cu I 5153.585, Cu II 3903.163, Cu III 2643.92, Fe I 5307.365, and Ne II 3334.87 A spectrum lines. These data are useful for determining the discharge channel-axis temperature
A.P. Petkov +4 more
openaire +1 more source
Plasma Science and Technology, 2007
A dielectric barrier surface discharge device was used to investigate the transition from a filamentary discharge to a glow discharge in air at different gas pressures. Discharge images and waveforms of the applied voltage and discharge current were recorded simultaneously, and it was found that the discharge could transit from filamentary to glow with
Li Xuechen, Li Lichun, Dong Lifang
openaire +1 more source
A dielectric barrier surface discharge device was used to investigate the transition from a filamentary discharge to a glow discharge in air at different gas pressures. Discharge images and waveforms of the applied voltage and discharge current were recorded simultaneously, and it was found that the discharge could transit from filamentary to glow with
Li Xuechen, Li Lichun, Dong Lifang
openaire +1 more source
Electron temperature in glow discharge plasmas
Journal of Physics D: Applied Physics, 1989The mechanism of electron temperature determination in a positive column of glow discharge plasmas was explained in terms of the balance of charged particle creation against the loss to the wall, in which Friedman's modification of Bohm's sheath criterion was taken into account.
H J Kim, K Matsuo, K Muraoka, M Akazaki
openaire +1 more source
Electron temperature in an electrodeless discharge.
AIAA Journal, 1968Electron temperature distributions in low pressure electrodeless discharge determined by spectrometric techniques and semicorona ...
openaire +1 more source
Discharge Temperatures From Pulverizers
Journal of Fluids Engineering, 1939Abstract In view of the fact that the temperature of discharge from coal pulverizers was of interest because of the effect that it might have on the amount of air passing through the preheater, and on the amount of uncontrollable air through the furnace, data were taken in a number of plants covering temperature of air entering ...
openaire +1 more source
Perpendicular temperature of the helium discharge in the c-stellarator
Journal of Nuclear Energy. Part C, Plasma Physics, Accelerators, Thermonuclear Research, 1965The perpendicular pressure and temperature of a current-carrying helium plasma in the C-Stellarator have been measured by means of a diamagnetic coil. In order to reduce recycling a pulsed gas-feed is used. The perpendicular temperature shows fairly good agreement with the resistivity temperature.
openaire +1 more source
Spectroscopic temperature measurements in a microwave discharge
Journal of Physics D: Applied Physics, 1996We report temperature measurements in a low-pressure hydrogen microwave plasma. Translational temperatures both of H and of (using Doppler broadening), as well as the rotational temperature of , are simultaneously determined. It is first shown that the rotational temperature of the excited state is not in equilibrium with the translational ...
L Tomasini +3 more
openaire +1 more source
Rapid Temperature Reduction of Thermal Discharge
Journal of the Hydraulics Division, 1975The temperature of a heated effluent stream, discharging from a thermoelectric power station, can be reduced by introducing a tempering water flow in the discharge channel upstream from the receiving body. This laboratory model study investigates the possibility of increasing the rate of temperature reduction by optimizing the mixing process between ...
Ronald D. Townsend, David L. Egar
openaire +1 more source
Excitation Temperatures in the Hollow Cathode Discharge
Applied Spectroscopy, 1981Excitation or spectroscopic temperatures have been determined for various operating conditions of a hollow cathode discharge. It was found that the temperatures measured do not significantly change over the range of conditions studied. These results are compared to those obtained in other low-pressure discharges.
D. M. Mehs, T. M. Niemczyk
openaire +1 more source

