Results 91 to 100 of about 25,088,946 (286)

Analisa Kondisi Transformator Daya Menggunakan Dissolved Gas Analysis (DGA)

open access: yes, 2023
— Transformer is one of the most important component in the electricity distribution system. The operation process of the Lahendong PLTP transformer requires oil as a cooling agent and insulator.
Tuegeh, Maickel   +2 more
core  

Composites of Shellac and Silver Nanowires as Flexible, Biobased, and Corrosion‐Resistant Transparent Conductive Electrodes

open access: yesAdvanced Functional Materials, EarlyView.
Shellac, a centuries‐old natural resin, is reimagined as a green material for flexible electronics. When combined with silver nanowires, shellac films deliver transparency, conductivity, and stability against humidity. These results position shellac as a sustainable alternative to synthetic polymers for transparent conductors in next‐generation ...
Rahaf Nafez Hussein   +4 more
wiley   +1 more source

On-Line Analysis of Oil-Dissolved Gas in Power Transformers Using Fourier Transform Infrared Spectrometry

open access: yesEnergies, 2018
To address the problem of on-line dissolved gas analysis (DGA) of a power transformer, a Fourier transform infrared (FT-IR) spectrometer was used to develop an analysis instrument. Carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), ethane (C2H6),
Xiaojun Tang   +4 more
doaj   +1 more source

A century of dissolved gas analysis - Part II

open access: yesTransformers Magazine, 2019
Future brings some changes to DGA. It is expected that offline DGA in standard laboratories will gradually disappear as a routine test and transformers without online DGA will be tested by using simple portable devices. The online sensors will be monitored from a central control room with a sophisticated artificial intelligence in an effort to predict ...
openaire   +4 more sources

Contribution to the improvement of the dissolved gas analysis techniques / [PDF]

open access: yes, 2012
There is a general agreement that in service conditions the quality of mineral insulating oils gradually deteriorates under the impact of electrical, thermal and environmental stresses. It is also widely accepted that only the incipient electrical failures such as hot spots and partial discharges are responsible for the gassing of oil. Knowing that the
openaire   +1 more source

Intermediate Resistive State in Wafer‐Scale Vertical MoS2 Memristors Through Lateral Silver Filament Growth for Artificial Synapse Applications

open access: yesAdvanced Functional Materials, EarlyView.
In MOCVD MoS2 memristors, a current compliance‐regulated Ag filament mechanism is revealed. The filament ruptures spontaneously during volatile switching, while subsequent growth proceeds vertically through the MoS2 layers and then laterally along the van der Waals gaps during nonvolatile switching.
Yuan Fa   +19 more
wiley   +1 more source

Shale Gas Content Calculation of the Triassic Yanchang Formation in the Southeastern Ordos Basin, China

open access: yesEnergies, 2017
Shale gas content is the key parameter for shale gas potential evaluation and favorable area prediction. Therefore, it is very important to determine shale gas content accurately. Generally, we use the US Bureau of Mines (USBM) method for coal reservoirs
Jiao Su, Yingchu Shen, Jin Hao, Bo Liu
doaj   +1 more source

Electrospun Wood‐Derived Biopolymers as Electrodes in Electrochemical Energy Storage Technologies

open access: yesAdvanced Functional Materials, EarlyView.
Electrospinning transforms wood‐derived cellulose and lignin into architecturally defined, binder‐free carbon electrodes with tuneable porosity and functionality. This review shows how fibre design enables decoupled charge and mass transport, enhancing performance across battery systems, while identifying key challenges in spinnability, scalability ...
Michael W. Thielke   +3 more
wiley   +1 more source

Biodegradable and Biocompatible Functional Polymers for Biomedical Applications

open access: yesAdvanced Functional Materials, EarlyView.
Biodegradable and biocompatible functional polymers integrate electrical, mechanical, and stimuli‐responsive functionalities while enabling programmed degradation under physiological conditions. This review introduces recent advances in conductive, shape‐memory, self‐healing, photocurable, and adhesive polymer systems, emphasizing material design ...
Won Bae Han   +5 more
wiley   +1 more source

Condition monitoring: Dissolved Gas Analysis for transformer health management [PDF]

open access: yes, 2018
Complex studies have led to the development of powerful methods to assess the health of the insulation system, and even the entire transformer, by periodically analyzing samples of the transformer oil.
McGrail, Tony
core   +1 more source

Home - About - Disclaimer - Privacy