Results 71 to 80 of about 646,559 (302)
Carbon‐free inert anodes are essential for decarbonizing aluminum electrolysis. This study investigates a recyclate‐based MgO‐316L steel composite anode tested under galvanostatic Hall–Héroult conditions in cryolite at 1000°C. Microstructural analysis reveals selective MgO fluorination, spinel and oxide layer formation, electrolyte infiltration, and ...
Serhii Yaroshevskyi +7 more
wiley +1 more source
Where to perform the dissolved gas analysis?
All the readers of Transformers Magazine and attendees of Transformer Academy already realize that DGA is one of the most comprehensive tests for oil-filled electrical devices. Also, readers well understand the complexity of these tests. This aspect is emphasized by all DGA standards, guides, and ample literature and research on DGA methodology.
openaire +2 more sources
Contribution to the improvement of the dissolved gas analysis techniques / [PDF]
There is a general agreement that in service conditions the quality of mineral insulating oils gradually deteriorates under the impact of electrical, thermal and environmental stresses. It is also widely accepted that only the incipient electrical failures such as hot spots and partial discharges are responsible for the gassing of oil. Knowing that the
openaire +1 more source
Dynamics of gas bubble growth in a supersaturated solution with Sievert's solubility law
This paper presents a theoretical description of diffusion growth of a gas bubble after its nucleation in supersaturated liquid solution. We study systems where gas molecules completely dissociate in the solvent into two parts, thus making Sievert's ...
A. E. Kuchma +4 more
core +1 more source
Removing Oxide Layers and Retaining Oxide‐Free Steel Surfaces by Polishing in Oxygen‐Free Atmosphere
In this study, the efficacy of wet mechanical polishing under an oxygen‐free atmosphere for deoxidation and the retention of an oxide‐free steel surface are elucidated using X‐ray photoelectron spectroscopy. The methodology proved successful; however, the results were highly dependent on the preparation of the solvents used to clean the samples after ...
Friedrich Bürger +2 more
wiley +1 more source
Correction to "Novel Probabilistic Neural Network Models Combined with Dissolved Gas Analysis for Fault Diagnosis of Oil-Immersed Power Transformers". [PDF]
Zhou Y, Tao L, Yang X, Yang L.
europepmc +2 more sources
A review of optical gas sensing technology for dissolved gas analysis in transformer oil
Dissolved gas analysis (DGA) of transformer oil can deeply understand the operation status of oil-immersed transformers, and detect early transformer failures as early as possible, thus achieving the purpose of preventing further damage to the ...
Jialiang Dai +17 more
doaj +1 more source
The formation of nonmetallic inclusions (NMIs) was investigated in this study, carrying out immersion tests for 30 min at a temperature of 1600°C with liquid high‐silicon electrical steel (Si ≈ 3 mass‐%) and different MgO–C refractories. Conventional MgO–C refractories were considered, as well as MgO–C refractories containing MgO–C recyclate and ...
Lukas Neubert +6 more
wiley +1 more source
Greenhouse gas emissions from wetlands are significantly promoted by global nitrogen input for changing the rate of soil carbon and nitrogen cycling, and are substantially affected by soil labile carbon and nitrogen conversely.
Mengli Chen +6 more
doaj +1 more source
We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas ...
Butler J P +22 more
core +1 more source

