Determination of transformer performance index based on dissolved gas analysis [PDF]
Dissolved Gas Analysis (DGA) is the single most widely used and most effective test to determine transformer’s operation conditions. The detection of gases generated in the transformer is the first available indication of the transformer malfunction ...
Md. Zain, Zainol Alam
core
ABSTRACT Identification of a chemical agent yields insights into its physicochemical properties. By examining the intrinsic characteristics and environment of a compound, information about its history can be gathered. The main objective of authentication/forensic approaches to chemicals is to trace the history of the compound's origin, regardless of ...
Carla Orlandi +6 more
wiley +1 more source
Feature Selection and Classification of Transformer Faults Based on Novel Meta-Heuristic Algorithm
Detecting transformer faults is critical to avoid the undesirable loss of transformers from service and ensure utility service continuity. Transformer faults diagnosis can be determined based on dissolved gas analysis (DGA).
El-Sayed M. El-kenawy +7 more
doaj +1 more source
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang +5 more
wiley +1 more source
ANALISIS KONDISI TRANSFORMATOR DAYA 20KV/150KV DENGAN METODE UJI DISSOLVED GAS ANALYSIS (DGA) DI PT.PJB PLTU REMBANG [PDF]
Permasalahan yang umum terjadi pada transformator saat beroperasi adalah timbulnya gas yang terlarut dalam minyak transformator yang disebut dengan fault gas .Fault gas ini timbul karena akibat dari kegagalan transformator yang dipicu dari kenaikan ...
Tohari, Muhamad +2 more
core
Transformator merupakan peralatan utama dalam pemasokan listrik dari unit pembangkitan menuju konsumen. Oleh karena itu, perlu perhatian khusus dalam pemeliharaan kinerja transformator agar tidak terjadi kerusakan pada transformator.
Abdul Syakur, Wildan Lazuardi
doaj +1 more source
ABSTRACT The complex diffusion of characteristic gases within oil‐immersed transformers significantly influences the timeliness between the fault occurrence and gas detection. So far, the gas transport processes and spatio‐temporal distributions remain inadequately understood.
Chunpeng Li +7 more
wiley +1 more source
Power Transformer Fault Diagnosis Based on Dissolved Gas Analysis by Correlation Coefficient-DBSCAN
The transformers work in a complex environment, which makes them prone to failure. Dissolved gas analysis (DGA) is one of the most important methods for oil-immersed transformers’ internal insulation fault diagnosis.
Yongxin Liu +4 more
doaj +1 more source
In South Africa, the growing power demand, challenges of having idle infrastructure, and power delivery issues have become crucial problems. Reliability enhancement necessitates a life-cycle performance analysis of the electrical power transformers.
Bonginkosi A. Thango
doaj +1 more source
ABSTRACT Dissolved gas analysis (DGA), widely used for fault diagnosis, can be significantly influenced by the presence of oxygen. Oxygen not only accelerates fluid degradation but also alters the type and concentration of fault gases generated, potentially leading to misinterpretation of transformer conditions if conventional DGA models are applied ...
Moïse Agouassi +4 more
wiley +1 more source