Results 51 to 60 of about 25,394,445 (190)
ANALISIS INDIKASI KEGAGALAN TRANSFORMATOR DENGAN METODE DISSOLVED GAS ANALYSIS [PDF]
Permasalahan yang umum pada operasional transformator daya adalah timbulnya kegagalan, baik kegagalan termal maupun kegagalan elektris. Kegagalan termal dan kegagalan elektris umumnya menghasilkan gas-gas berbahaya yang biasa dikenal sebagai fault gas ...
Karnoto , Karnoto +2 more
core +1 more source
ABSTRACT In situ monitoring of oil‐dissolved gases without degassing in oil‐immersed equipment has become a promising approach. Herein, a direct sensing strategy utilising conductive metal–organic frameworks (cMOF) is proposed to develop a sensor capable of detecting multiple characteristic dissolved gases.
Zhiyong Lv +6 more
wiley +1 more source
Insulation system diagnosis in power transformers using DGA analysis and Megger DC
Dissolved gas chromatography (DGA) analysis and Megger DC insulation tests are performed to diagnose the condition of a power transformer. In this context, the objective of this study is to assess whether there is a relationship between both types of ...
Juan Sebastian Juris Zapata +3 more
doaj +1 more source
Internal Fault Diagnosis in Power Transformers Using Dissolved Gas Analysis and Deep Learning Technique [PDF]
The most common method for detecting internal faults in power transformers is the dissolved gas analysis (DGA) technique. The application of deep learning approaches in analyzing dissolved gases in oil faces challenges related to the scarcity of reliable
Mohsen Kariman Majd, Mohsen Niasati
doaj +1 more source
Nitride MXenes remain constrained by a persistent gap between computational prediction and experimental realization. This Review identifies the thermodynamic, kinetic, and chemical barriers limiting their synthesis, critically evaluates emerging fabrication routes, and proposes a multidimensional computational‐experimental framework to accelerate the ...
Naresh Varnakavi, Masoud Soroush
wiley +1 more source
Analysis and interpretation of dissolved gases in transformer oil: A case study [PDF]
Condition monitoring plays a vital role in any asset management plan. Dissolved gas analysis is a routine test carried out on power transformers to monitor their condition.
H. A. Fonseka +5 more
core +1 more source
IBPS‐3A, an acidic heteropolysaccharide purified from sweet potato vines, was structurally characterized to possess a backbone consisting of →4)‐α‐D‐GalpA‐(1→ and →2,4)‐α‐L‐Rhap‐(1→ linkages with arabinogalactan side chains. Further investigation revealed that IBPS‐3A induced M1 polarization in RAW264.7 macrophages, stimulating the secretion of TNF‐α ...
Yuqi Shi +6 more
wiley +1 more source
ANALISIS KEGAGALAN ISOLASI MINYAK TRANSFORMATOR 27 MVA PLTG 1 JAKABARING BERDASARKAN HASIL UJI DISSOLVED GAS ANALYSIS (DGA) [PDF]
Metode indentifikasi kandungan gas yaitu dengan Dissolved Gas Analysis (DGA) merupakan metode konvensiona luntuk mengidentifikasi kandungan gas yang terlarut dalam minyak trafo.
Fithri, Normaliaty, Auliya, Januar Rizky
core
With the growing interest in monitoring and diagnostic techniques for assessing transformer condition, dissolved gas analysis (DGA) stands out as a crucial diagnostic tool to detect electrical and thermal faults in liquid‐immersed transformers ...
Gechen Bian +3 more
doaj +1 more source
Mg2+ confined within poly(heptazine imide) acts as a heterogenized interfacial charge bridge capable to couple synergistically the semiconductor with Pt co‐catalysts, thus enhancing hydrogen evolution. Through water polarization and hydroxide stabilization, a dynamic Mg2+‐OHδ−‐Hδ+‐Pt motif facilitates proton transfer and overcomes interfacial electron ...
Gabriel A. A. Diab +17 more
wiley +1 more source