Results 11 to 20 of about 1,644,928 (302)

Improvement of Distance Protection with SVM on PV-Fed Transmission Lines in Infeed Conditions

open access: yesEnergies, 2023
Photovoltaic (PV) power plants have comparatively weak infeed characteristics, unlike conventional synchronous generators. The controllability of grid-connected inverters and the limited overcurrent capability of power electronic devices means that the ...
Yasar Beyazit Yoldas, Recep Yumurtacı
doaj   +1 more source

Enhancing Distance Protection of Long Transmission Lines Compensated With TCSC and Connected With Wind Power

open access: yesIEEE Access, 2021
Thyristor controlled series compensation (TCSC) is widely used in long transmission lines to mainly improve power transfer capability. However, TCSC produces complicated impedance that negatively affects distance protection operation.
Ahmed Abdel Rahman Mohamed   +2 more
doaj   +1 more source

Fault Studies and Distance Protection of Transmission Lines Connected to DFIG-Based Wind Farms

open access: yesApplied Sciences, 2018
Doubly fed induction generator (DFIG) based wind farms are being increasingly integrated into power grids with transmission lines, and distance protection is usually used as either the main or the backup protection for the transmission line.
Bin Li, Junyu Liu, Xin Wang, Lili Zhao
doaj   +1 more source

Impact of inverter-based resources on transmission line relaying -part II: power swing protection

open access: yesFrontiers in Electronics, 2023
The power swing characteristic of transmission lines (TLs) can be affected by the large-scale integration of inverter-based resources (IBRs), resulting in the maloperation of the legacy power swing blocking (PSB) and out-of-step tripping (OST) functions.
Amin Jalilian, Duane A. Robinson
doaj   +1 more source

A Setting Optimization Strategy for Distance Protection Ⅱ after Connection of Synchronous Condensers

open access: yesZhongguo dianli, 2022
The large-scale access of synchronous condensers (SCs) to the power grid will reduce the protection range of the distance protection section Ⅱ, and reasonable optimization of the protection setting is a feasible way to solve this problem. For this reason,
Dongsheng LI   +4 more
doaj   +1 more source

Assessing the reliability of adaptive power system protection schemes [PDF]

open access: yes, 2012
Adaptive power system protection can be used to improve the performance of existing protection schemes under certain network conditions. However, their deployment in the field is impeded by their perceived inferior reliability compared to existing ...
Abdulhadi, Ibrahim Faiek   +3 more
core   +1 more source

Radially restricted linear energy transfer for high-energy protons: A new analytical approach [PDF]

open access: yes, 1994
Radially restricted linear energy transfer (LET) is a basic physical parameter relevant to radiation biology and radiation protection. In this report a convenient method is presented for the analytical computation of this quantity without the need for ...
A Chatterjee   +11 more
core   +1 more source

Impact of Apparent Reactance Injected by TCSR on Distance Relay in Presence Phase to Earth Fault

open access: yesAdvances in Electrical and Electronic Engineering, 2013
This research paper presents the impact study of apparent reactance injected by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the measured impedance of a 400 kV single electrical transmission line in ...
Mohamed Zellagui, Abdelaziz Chaghi
doaj   +1 more source

To be or not to be an auctioneer: Some thoughts on the legal nature of online eBay auctions and the protection of consumers [PDF]

open access: yes, 2008
This paper discusses the legal classification of online “eBay” auctions. The discussion has key implications on the scope of consumer protection law as sale by auctions are, for example, excluded from the scope of the Consumer Protection (Distance ...
B. W. Harvey   +14 more
core   +3 more sources

Analysis of the equivalent fault characteristics of DC system and its impact on distance protection based on power-frequency variation

open access: yesThe Journal of Engineering, 2019
Here, the response characteristics of high-voltage DC (HVDC) control system are studied in the case that fault occurs in the sending-end AC system. Then the characteristics of DC system which is equivalent to power-frequency variation impedance in the ...
Dongxiao Cai, Haifeng Li, Xinchi Zhu
doaj   +1 more source

Home - About - Disclaimer - Privacy