Results 11 to 20 of about 311,533 (268)
Adaptive distance protection for microgrids [PDF]
Due to the increasing penetration of distributed generation resources, more and more microgrids can be found in distribution systems. This paper proposes a phasor measurement unit based distance protection strategy for microgrids in distribution system. At the same time, transfer tripping scheme is adopted to accelerate the tripping speed of the relays
Hengwei Lin +3 more
openaire +2 more sources
Distance protection for microgrids in distribution system [PDF]
Owing to the increasing penetration of distributed generation, there are some challenges for the conventional protection in distribution system. Bidirectional power flow and variable fault current because of the various operation modes may lead to the selectivity and sensitivity of the overcurrent protection decreased.
Hengwei Lin +3 more
openaire +3 more sources
Thyristor controlled series compensation (TCSC) is widely used in long transmission lines to mainly improve power transfer capability. However, TCSC produces complicated impedance that negatively affects distance protection operation.
Ahmed Abdel Rahman Mohamed +2 more
doaj +1 more source
Impact of inverter-based resources on transmission line relaying -part II: power swing protection
The power swing characteristic of transmission lines (TLs) can be affected by the large-scale integration of inverter-based resources (IBRs), resulting in the maloperation of the legacy power swing blocking (PSB) and out-of-step tripping (OST) functions.
Amin Jalilian, Duane A. Robinson
doaj +1 more source
A Differential-Distance Protection-Based Algorithm for Securing Double-Circuit Transmission Lines Against False Data Injection Cyberattacks [PDF]
Nowadays, communication networks play a crucial role in the integrated management of power systems, improving operational conditions, and implementing protective algorithms.
Mohammad Amin Mazaheri +1 more
doaj +1 more source
A Setting Optimization Strategy for Distance Protection Ⅱ after Connection of Synchronous Condensers
The large-scale access of synchronous condensers (SCs) to the power grid will reduce the protection range of the distance protection section Ⅱ, and reasonable optimization of the protection setting is a feasible way to solve this problem. For this reason,
Dongsheng LI +4 more
doaj +1 more source
Impact of Apparent Reactance Injected by TCSR on Distance Relay in Presence Phase to Earth Fault
This research paper presents the impact study of apparent reactance injected by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the measured impedance of a 400 kV single electrical transmission line in ...
Mohamed Zellagui, Abdelaziz Chaghi
doaj +1 more source
Here, the response characteristics of high-voltage DC (HVDC) control system are studied in the case that fault occurs in the sending-end AC system. Then the characteristics of DC system which is equivalent to power-frequency variation impedance in the ...
Dongxiao Cai, Haifeng Li, Xinchi Zhu
doaj +1 more source
State-of-the-art on the protection of FACTS compensated high-voltage transmission lines: a review
In recent years, the inclusion of flexible AC transmission systems (FACTS)-based compensating devices such as a thyristor-controlled series capacitor (TCSC) and a unified power flow controller (UPFC) has been increased in high-voltage power transmission ...
Sauvik Biswas, Paresh Kumar Nayak
doaj +1 more source
Series capacitors increase the power transfer limit of transmission lines. However, the protection of series compensated lines using only local measurement is challenging. Phasor based distance protection experiences delay and directional problems in the
Md. Tanbhir Hoq +2 more
doaj +1 more source