Results 181 to 190 of about 139,040 (269)
A custom shape memory polymer material selection process relates quantitative application criteria (e.g., compression garment yarns) to material characterization information. The selected materials are manufactured into yarn geometries, which expand the design space by creating structural stress‐strain profiles beyond the nominal material stress‐strain
Michaela Andrews +2 more
wiley +1 more source
Theoretical aspects of nanofluid peristaltic transport in tapered wavy structure. [PDF]
Tanveer A, Imtiaz S, Saleem S.
europepmc +1 more source
An in situ electroplating approach for MEX 3D printing is proposed, enabling copper deposition during the fabrication of conductive polymers. The method combines a printer‐integrated plating head, ML‐based g‐code control, and stop‐and‐go printing, achieving near‐bulk copper conductivity and enabling fully embedded, assembly‐free electronic components ...
Gianluca Percoco +5 more
wiley +1 more source
Friendship fosters well-being, exclusion may hurt girls' mathematics: a two-wave cross-lagged panel model of peer relations, affect, and achievement. [PDF]
Lintner T.
europepmc +1 more source
A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein +2 more
wiley +1 more source
The Role of Information Entropy in Symmetry of Euclidean Polygons. [PDF]
Vopson MM.
europepmc +1 more source
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani +9 more
wiley +1 more source
Enhancing symbolic image classification through Gaussian copulas and optimized distinguishing points. [PDF]
Winarni S +9 more
europepmc +1 more source
A fully organic UV threshold dosimeter is developed by exploiting the oxygen‐sensitive room‐temperature phosphorescence of a purely organic emitter in a polymer matrix. Upon reaching a specific cumulative UV dose, photochemical oxygen depletion triggers a sharp, high‐contrast emission.
Tim Achenbach +3 more
wiley +1 more source

