Results 91 to 100 of about 15,150 (306)

Optimal size and siting of multiple DG and DSTATCOM in radial distribution system using Bacterial Foraging Optimization Algorithm

open access: yesAin Shams Engineering Journal, 2016
In this paper, a novel approach to determine the optimal location and sizing of Distribution Generation (DG) and Distribution STATic COMpensator (DSTATCOM) is analyzed, and the objective function is formulated for minimizing power loss, operational costs
K.R. Devabalaji, K. Ravi
doaj   +1 more source

Influence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of a silane‐doped argon atmosphere on the chemical composition and temperature of a thermal nontransferring argon plasma is investigated using optical emission spectroscopy. As a result of the high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule, even a silane addition of 0.01 vol ...
Lena Kreie   +4 more
wiley   +1 more source

Performance analysis of FPGA controlled four-leg DSTATCOM for multifarious load compensation in electric distribution system

open access: yesEngineering Science and Technology, an International Journal, 2018
A field programmable gate array (FPGA) controlled four-leg distribution static compensator (FL-DSTATCOM) has been implemented to achieve harmonic alleviation, supply current balancing, compensation of reactive power and current flow in the neutral ...
Azhagesan Dheepanchakkravarthy   +4 more
doaj   +1 more source

Four‐Point Bending Tests at High Temperatures on Commercial MgO‐C Refractory Bricks with and Without Recyclate Considering Different Carbon Contents

open access: yesAdvanced Engineering Materials, EarlyView.
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm   +5 more
wiley   +1 more source

Analysis of Techno–Economic and Social Impacts of Electric Vehicle Charging Ecosystem in the Distribution Network Integrated with Solar DG and DSTATCOM

open access: yesEnergies
In this work, a comprehensive planning framework for an electric vehicle charging ecosystem (EVCE) is developed, incorporating solar distributed generation (DG) and a distribution static compensator (DSTATCOM), to assess their long-term techno–economic ...
Ramesh Bonela   +6 more
doaj   +1 more source

Resistance Rapid Heating of Aluminum Coatings in an Extreme High Vacuum–Adequate Atmosphere for Hot Stamping

open access: yesAdvanced Engineering Materials, EarlyView.
The subject of this work is the development of a corrosion‐protective coating on steel sheets for form hardening. Rapid heating in an extreme high vacuum (XHV)‐adequate atmosphere is a useful method to prevent oxidation during alloying of 22MnB5 and aluminum to obtain a metallurgical bonding.
Lorenz Albracht   +5 more
wiley   +1 more source

Photovoltaic based distribution static compensator for power quality improvement

open access: yesInternational Journal of Electrical Power & Energy Systems, 2012
Abstract This paper deals with a model of photovoltaic (PV) array or battery operated DC/DC boost converter fed three-leg VSC (Voltage Source converter) with star delta transformer for power quality improvement. A synchronous reference frame theory is proposed for three-phase four-wire DSTATCOM (Distribution Static Compensator) which includes voltage
V. Kamatchi Kannan, N. Rengarajan
openaire   +1 more source

Surface Tension Measurement of Ti‐6Al‐4V by Falling Droplet Method in Oxygen‐Free Atmosphere

open access: yesAdvanced Engineering Materials, EarlyView.
In this article, the temperature‐dependent surface tension of free falling, oscillating Ti‐6Al‐4V droplets is investigated in both argon and monosilane doped, oxygen‐free atmosphere. Droplet temperature and oscillation are captured with one single high‐speed camera, and the surface tension is calculated with Rayleigh's formula.
Johannes May   +9 more
wiley   +1 more source

Research on output feedback control [PDF]

open access: yes
In designing fixed order compensators, an output feedback formulation has been adopted by suitably augmenting the system description to include the compensator states.
Calise, A. J., Kramer, F. S.
core   +1 more source

Phase Field Failure Modeling: Brittle‐Ductile Dual‐Phase Microstructures under Compressive Loading

open access: yesAdvanced Engineering Materials, EarlyView.
The approach by Amor and the approach by Miehe and Zhang for asymmetric damage behavior in the phase field method for fracture are compared regarding their fitness for microcrack‐based failure modeling. The comparison is performed for the case of a dual‐phase microstructure with a brittle and a ductile constituent.
Jakob Huber, Jan Torgersen, Ewald Werner
wiley   +1 more source

Home - About - Disclaimer - Privacy