For the system with all added components, the total revenue is about $15.3 million, and the total investment cost is about $11.3 million. So, the total profit for the 15‐year project is about $4 million, equivalent to 35.38% of the total investment cost.
My Ha Le +2 more
wiley +1 more source
This paper suggests the optimal placement of different flexible alternating current transmission system (FACTS) devices using various metaheuristic methods associated with effective cost management in the distribution network. The outcomes show that the proposed WOA technique generates more upshot than any other evolutionary algorithms in cost ...
Honey Baby +4 more
wiley +1 more source
A two‐stage operational planning model is developed for PV hosting capacity problems in the distribution network, which considers both operational practice by enhancement of HC of PV and economical operational limits by minimization of total planning cost.
Rezvaneh Golnazari +3 more
wiley +1 more source
Modeling, design and analysis of different controllers for DSTATCOM
This paper deals with different control strategies for DSTATCOM (Distribution Static Compensator) for power quality improvement for a three-phase, three-wire distribution system.
Gupta, J. R. P. +7 more
core +1 more source
In order to logically allocate reactive power compensators in distribution networks, a method based on fuzzy logic is presented in this paper to take into account the amount of network load in all hours of the study period, and at the same time, the run time of the simulations will be very short so that it is possible to solve such problems.
Ali Solati +3 more
wiley +1 more source
Power factor correction and zero voltage regulation in distribution system using DSTATCOM
This paper presents an implementation of three-phase distribution static compensator (DSTATCOM) using single phase p-q theory based control algorithm for functions of DSTATCOM in power factor correction (PFC) zero voltage regulation (ZVR) mode under ...
Singh, Bhim +7 more
core +1 more source
• As the main contribution, simultaneous optimisation of the site and size of service transformers, WTs and PVs is investigated with respect to the impact of the load profile. In other words, in a distribution network, since it is important to optimally allocate service transformers and various factors can affect the optimal results, this paper focuses
Mohammad Ali Alipour, Alireza Askarzadeh
wiley +1 more source
Study of power quality assessment for a photo-voltaic based Distribution Static Compensator (DSTATCOM) [PDF]
This thesis presents an idea of PV cell or battery based dc to dc boost converter which is served to a voltage source converter (VSC) for enhancement of quality of power.
Rana, G, Badu, A J
core
Power quality disturbances (PQDs), including voltage sags, swells, harmonics, transients, flickers, and interruptions, affect the reliability and efficiency of modern power distribution systems. This study introduces a novel heuristic model that integrates a long short‐term memory (LSTM) deep neural network with the sea lion optimization (SLO ...
Anupama S. Kumar +2 more
wiley +1 more source
Sliding mode control of static shunt compensator
This paper deals with the implementation of sliding mode control (SMC) strategy for a four-leg voltage supply converter (VSC) based distribution static synchronous compensator (DSTATCOM) for power quality improvement in a three phase four-wire power ...
Singh, Bhim +5 more