Results 81 to 90 of about 1,332 (171)
Application of a three‐phase unified power quality conditioner in a microgrid
The UPQC system designed in this study used a series inverter to compensate the voltage balance sag–swell component, providing a stable voltage for the back‐end load. When the load was unbalanced, the feeder current was unbalanced. The shunt inverter compensated for the unbalanced current balanced the feeder current to improve power quality.
Tsung‐Hsun Wu +2 more
wiley +1 more source
Fuzzy Logic Based VCM and CCM Controlled DSTATCOM for Improved Power Quality [PDF]
Power Quality problems in distribution systems can be solved by providing suitable shunt compensation, one such device is Distribution static compensator (DSTATCOM). Power quality issues generally arise due to high-energy demand loads such as pulse loads.
Mrs.R.Naveena Bhargavi
core +1 more source
1. Performance of least mean square (LMS), sign‐error LMS, ϵ‐NLMS, and least mean fourth (LMF)‐based adaptive control algorithms with different learning rates has been analysed. 2. PV array has been integrated into a single‐stage topology with an maximum power point tracking (MPPT) facility. 3.
Dinanath Prasad +6 more
wiley +1 more source
Integrate renewable energy system (RES) into grid‐connected load system in enhancing reliability and reducing losses. However, integrating these systems introduce power quality (PQ) issues, especially with non‐linear, critical, and imbalanced loads. Addressing this, a hybrid mantis search‐reptile search algorithm combined with a unified power quality ...
Hariprabhu Manoharan +3 more
wiley +1 more source
Power Angle Control Scheme for Integration of UPQC in Grid Connected PV System [PDF]
The quality of electric power is greatly affected by the proliferation of non-linear loads in electrical energy processing applications like switched mode power supplies, electric motor drives, battery chargers, etc., The custom power devices like UPQC ...
Chaitanya, Nakka Pruthiv
core
Abstract The importance of resolving stability concerns in weak AC grid‐connected doubly fed induction generator (DFIG) wind energy systems during low‐voltage ride‐through (LVRT) events cannot be ignored, given the increasing popularity of wind power‐based microgrids.
Saqif Imtiaz +5 more
wiley +1 more source
Five-Level DSTATCOM for Power Quality Improvement Using Intelligent Controllers [PDF]
Addressing power quality issues is an important task for power engineers as a small disturbance in power system can initiate hefty disaster to the loads connected at user point.
Singh Satendra +3 more
doaj +1 more source
An improved model predictive control with Luenberger state observer is proposed for LC‐coupling hybrid active power filter. This article utilizes the Luenberger observer to mitigate the steady‐state error without additional sensors, and the one‐sampling‐time delay compensation is given for the digital control delay.
Yuan Lv +5 more
wiley +1 more source
CHBMLI based DSTATCOM for power quality improvemt in a three-phase three-wire distribution system with PI controller [PDF]
This paper presents a cascaded h-bridge (CHB) multilevel inverter (MLI) based MLI based distribution static synchronous compensator (DSTATCOM). The main objective of this paper is to reduce source current harmonics in the distribution system by using a ...
Chenchireddy, Kalagotla +5 more
core +2 more sources
Simultaneous optimal placement and sizing of DSTATCOM and parallel capacitors in distribution networks using multi-objective PSO [PDF]
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new ...
Bahmanyar, A +5 more
core +1 more source