Results 41 to 50 of about 1,253,060 (256)

Enhancement of household refrigerator energy efficiency by studying the effect of refrigerant charge

open access: yesJournal of Thermal Engineering, 2021
Experiments were carried out initially by considering pure R134a and hydrocarbon refrigerant mixtures such as (R290/R600a) (HCM1 44/56, HCM2 50/50, HCM3 54/46, HCM4 64/36, and HCM5 74/26 wt %).
S.k. GUGULOTHU
doaj   +1 more source

Modelling refrigerating compartment of frost-free domestic refrigerators [PDF]

open access: yesGlobal NEST Journal, 2013
This paper is focussed on the study of the air movement and temperature distribution inside refrigerating compartment of household frost-free refrigerators. It is well known that the correct air circulation and temperature distribution inside the refrigerated chamber are two of the most important factors that affect refrigerator efficiency.
openaire   +1 more source

Experimental and Theoretical Investigation of Propane/Butane and Propane/Isobutane Mixtures as an Alternative to R134a in a Domestic Refrigerator [PDF]

open access: yesEngineering and Technology Journal, 2014
In the present work, theoretical and experimental investigation have been carried out with two hydrocarbon refrigerant mixtures as a possible alternatives to R134a. Theoretical performance of an ideal vapor compression refrigeration cycle using R290/R600
Wahid S. Mohammad, Assad Oda Jassim
doaj   +1 more source

Performance Simulation Of Single-Evaporator Domestic Refrigerator Using Alternative Refrigerants [PDF]

open access: yes, 2003
The search for well-functioning and energy-optimized refrigeration systems has made modeling and simulation of such systems an important tool for the industry in terms of product development.
Salam Hadi Hussain   +3 more
core   +1 more source

ENERGY PERFORMANCE OF HYDROCARBON REFRIGERANT AS A POSSIBLE ALTERNATIVE REFRIGERANT TO R134A IN DOMESTIC REFRIGERATORS [PDF]

open access: yesJournal of Al-Azhar University Engineering Sector, 2019
The performance of a domestic refrigerator is theoretically assessed in this study. Therefrigerator utilizes R1234yf as an alternative refrigerant for R134a. The performance isevaluated for three condensing temperatures, specifically, 30, 40, and 50°C at differentevaporator temperatures, ranging −30 and 0°C.
Tamer Hassan, N Mahmoud, M El-Morsi
openaire   +1 more source

Unraveling ovarian histology: The key morphological aspects that spur the development of the Fossa ovarii in equine

open access: yesThe Anatomical Record, EarlyView.
Abstract The equine ovary exhibits unique structural and developmental features that distinguish it from those of other domestic species, including the presence of an ovulation fossa and an inversion of cortical and medullary layers. This study aimed to investigate the morphostructural development of the equine fetal ovary, with particular emphasis on ...
Laura Ver Goltz   +5 more
wiley   +1 more source

Modeling and Simulation of the Operation of a Rotary Magnetic Refrigerator

open access: yesJournal of Thermal Science and Technology, 2011
Magnetic refrigeration is a new environmentally benign technology and a promising alternative to conventional vapor-cycle refrigeration. Among these technologies the household refrigerator without a freezing compartment shows very good prospects for a ...
Didier VUARNOZ   +4 more
doaj   +1 more source

Microfiltration (MF) and Ultrafiltration (UF) for Sewage and Surface Water Concentration for SARS‐CoV‐2 and Other Enveloped Viruses' Detection in Wastewater‐Based Epidemiology (WBE)

open access: yesBiotechnology and Bioengineering, EarlyView.
ABSTRACT This study objective was to evaluate hollow fiber membranes for concentration of enveloped enteric viruses in sewage and surface water samples. Microfiltration (MF, 0.2 µm nominal pore size) and ultrafiltration (UF, 100 kDa molecular weight cut‐off) hollow fiber membranes were compared for the concentration of the bovine respiratory syncytial ...
Rodrigo Almeria Ragio   +3 more
wiley   +1 more source

Theoretical analysis of a Low GWP Refrigerants as a Drop in substitute of R134a in a Domestic Refrigerator [PDF]

open access: yesIranica Journal of Energy and Environment, 2018
Now a days Fridges and Air-conditioners are mostly used in domestic environment. The CFCs have been almost ruled out since 1995 due to their huge impact on the ozone layer, due to the above problem HFC refrigerants are introduced but these are having a ...
M. Shaik Sk, K. Srinivas
doaj   +1 more source

The management of the domestic refrigeration: microbiological status and temperature [PDF]

open access: yesBritish Food Journal, 2014
Purpose – The purpose of this paper is to provide information on the consumer management of refrigerated food, establish the level and the incidence of bacterial contamination and operating temperatures in domestic refrigerators from north and centre Italy.
Vegara, Alberto   +5 more
openaire   +5 more sources

Home - About - Disclaimer - Privacy