Results 321 to 330 of about 11,911,230 (418)
Quality by Design Tool Assessed Ultraperformance Liquid Chromatography Method for the Analysis of Remogliflozin and Teneligliptin in Oral Dosage Form. [PDF]
Menda J+5 more
europepmc +1 more source
Abstract Purpose This work introduces BreastWatch, a Varian Eclipse script tool designed to help medical physicists, dosimetrists, and radiation oncologists easily inspect and improve External Beam Breast Treatment (EBBT) plans using automatic evaluation of protocol dose‐constraints enhanced by a Community‐Based approach.
Stefano Agostinelli+8 more
wiley +1 more source
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab+6 more
wiley +1 more source
Abstract Purpose This study aims to evaluate the accuracy of the frameless linear accelerator‐based stereotactic radiosurgery (FSRS) system incorporating cone‐beam CT (CBCT), six degrees of freedom (6‐DoF) couch, room laser, and surface image‐guided (SG) systems.
Hao‐Wen Cheng+4 more
wiley +1 more source
Abstract Background Dual‐energy cone‐beam CT (DE‐CBCT) has become subject of recent interest due to the ability to produce virtual monoenergetic images (VMIs) with improved soft‐tissue contrast and reduced nonuniformity artifacts. However, efficient production and optimization of VMIs remains an under‐explored part of DE‐CBCT's application.
Andrew Keeler+4 more
wiley +1 more source
Abstract Purpose Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the ...
Mustafa Çağlar+8 more
wiley +1 more source
Comprehensive clinical evaluation of novel 4DCT‐based lung function imaging methods
Abstract Purpose Methods have been developed that apply image processing to 4DCTs to generate 4DCT‐ventilation/perfusion lung imaging. Traditional methods for 4DCT‐ventilation rely on Hounsfield‐Unit (HU) density‐change methods and suffer from poor numerical robustness while not providing 4DCT‐perfusion data.
Ehsan Golkar+6 more
wiley +1 more source
Abstract Background The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images ...
Andrew J. Krupien+8 more
wiley +1 more source
Abstract Purpose Volumetric‐modulated arc therapy (VMAT) treatment planning allows a compromise between a sufficient coverage of the planning target volume (PTV) and a simultaneous sparing of organs‐at‐risk (OARs). Particularly in the case of lung tumors, deciding whether it is possible or worth spending more time on further improvements of a treatment
Johann Brand+4 more
wiley +1 more source