Results 11 to 20 of about 10,586,048 (306)

Estimation of Operator Dose by Dose Area Product Meter

open access: yesJapanese Journal of Radiological Technology, 2006
Because of the more advanced and more complex procedures in interventional radiology (IVR), longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. Operator doses arising from the use of X-rays are mainly due to scattered radiation.
Hajime Sakamoto, Yoshitomo Sano
exaly   +4 more sources

Effective Dose Evaluation of Cerebral Angiography Using Kerma Area Product and Development of Effective Dose Conversion Factors [PDF]

open access: yesDiagnostics
Background/Objectives: Transfemoral cerebral angiography (TFCA) involves significant radiation exposure because of prolonged fluoroscopy and repeated imaging sequences.
Jeongbok Min, Jungsu Kim
doaj   +2 more sources

ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

open access: yesРадиационная гигиена, 2018
Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution
A. V. Vodovatov   +4 more
doaj   +2 more sources

Dose-Area Product Determination and Beam Monitor Calibration for the Fixed Beam of the Shanghai Advanced Proton Therapy Facility

open access: yesApplied Sciences, 2022
Research conducted to-date, makes use of the IBA-Lynx scintillating screen and radiochromic film to analyze the proton field uniformity for dose-area product (DAP) determination.
Libing Zhu   +3 more
doaj   +3 more sources

Decadal Changes in Institutional Diagnostic Reference Levels for X-Ray Angiography: A Retrospective Comparative Study [PDF]

open access: yesJournal of Imaging
Angiography is a key imaging modality for the diagnosis and treatment of vascular diseases, and the growing sophistication of interventional procedures has heightened the need for radiation dose optimization. Diagnostic Reference Levels (DRLs) are widely
Ioannis Antonakos   +10 more
doaj   +2 more sources

No reduction of radiation dose following the introduction of dose–area product measurement in endoscopic retrograde cholangiopancreatography

open access: yesEuropean Journal of Gastroenterology & Hepatology, 2015
During radiological examinations such as endoscopic retrograde cholangiopancreatography (ERCP), it is recommended to record the dose-area product (DAP) to reduce the patient's and the physician's exposure to ionizing radiation. However, the effect of DAP measurement on the total radiation dose in ERCP procedures has never been assessed.This study ...
A. Kruit   +5 more
semanticscholar   +4 more sources

Dose area product

open access: yesRadiopaedia.org, 2020
D. Bell, Z. Vajuhudeen
semanticscholar   +2 more sources

Measurement of dose‐area product with GafChromic XR Type R film

open access: yesJournal of Applied Clinical Medical Physics, 2005
Many of the newer X‐ray machines are equipped with electronic means to provide dose–area product (DAP) information. For machines without that ability, an alternative method is to record radiation on a film that can handle a large amount of cumulative exposure. The use of GafChromic XR Type R film was investigated for this purpose by placing it at the X‐
Thomas, George   +6 more
exaly   +3 more sources

Survey of dose area product received by patients undergoing common radiological examinations in four centers in Nigeria

open access: yesJournal of Applied Clinical Medical Physics, 2012
Patient dosimetry studies in diagnostic radiology in Nigeria have been on measurement of entrance skin dose and effective dose. Another important and easy to measure radiation dose descriptor that could be used to assess patient dose in radiological ...
B. I. Akinlade, I. P. Farai, A. Okunade
exaly   +2 more sources

Characteristic Evaluation and Clinical Usefulness of Dose Area Product Meter at Radiography

open access: yesJapanese Journal of Radiological Technology, 2011
Philips DigitalDiagnost, a digital radiographic system mounting flat panel detector (FPD), can display dose area data (DiDi dose) calculated by examination parameters. We evaluated its fundamental characteristics and compared the values of DiDi dose andactual measured data obtained by the area dose product meter (PD-4100L). Tendency of varied values of
Seiichi Masuda
exaly   +4 more sources