Results 31 to 40 of about 1,847,691 (292)
Diameter of a double lumen tube size: 37CH (left) and single lumen tube size: 8.0 I.D (right).
Diameter of a double lumen tube size: 37CH (left) and single lumen tube size: 8.0 I.D (right).
Anna Smelik (5745920) +6 more
core +1 more source
A rare case of double lumen in the fallopian tube [PDF]
Mullerian duct anomaly is seldom reported in the literature. Isolated congenital anomalies of the fallopian tubes are uncommon and are often overlooked due to the limited data available about this entity.
Mulla, Arsala +3 more
core +1 more source
Innovative Approach to Difficult Airway Management: Utilizing the Cook® Airway Exchange Catheter for Double-Lumen Tube Intubation. [PDF]
BACKGROUND The Cook® Airway ExchangeCatheter (Cook® AEC, Cook Group Incorporated, Bloomington, Indiana, USA) is an 83-cm-long graduated hollow tube with an external diameter of 11, 14, or 19 French, commonly used for tracheal tube replacement.
Maseri A +4 more
europepmc +2 more sources
Bronchial rupture with a left-sided polyvinylchloride double-lumen tube
Bronchial rupture after intubation with a double-lumen endobronchial tube has been infrequently reported. Overinflation of the bronchial cuff was speculated to be a frequent cause of the bronchial damage.
Aykac, B +7 more
core +1 more source
Lung Separation in the Morbidly Obese Patient
Lung separation techniques in the morbidly obese patient undergoing thoracic or esophageal surgery may be at risk of complications during airway management.
Javier H. Campos, Kenichi Ueda
doaj +1 more source
DOUBLE LUMEN TUBE PLACEMENT WITH THE BULLARD LARYNGOSCOPE [PDF]
Placement of double lumen tubes (DLTs) in both normal and difficult airways may be considerably more difficult than standard laryngoscopy and intubation using standard tracheal tubes. Alternative techniques to place DLTs have not been uniformly successful and alternative tracheal tubes do not provide the versatility afforded by the DLT.
G B, Shulman, N R, Connelly
openaire +3 more sources
Unilateral postobstructive pulmonary edema following double-lumen endobronchial tube intubation [PDF]
SummaryHerein, we report a male patient underwent a video-assisted thoracoscopic resection of left lower lobe intralobar bronchopulmonary sequestration that developed unilateral postobstructive pulmonary edema following double-lumen endobronchial tube ...
Kiatboonsri, Sumalee +2 more
core +1 more source
Golgi enzymes are retrieved from the plasma membrane to the trans‐Golgi network
Golgi enzymes are traditionally considered resident proteins retained within the Golgi apparatus. Here, we demonstrate that a subset transiently reaches the cell surface and is subsequently retrieved to the trans‐Golgi network via retrograde transport. Using a nanobody‐based toolkit, we uncover a dynamic trafficking cycle of several Golgi enzymes.
Dominik P. Buser, Tina Junne
wiley +1 more source
Background The objective of this study was to evaluate a modern combined video laryngoscopy and flexible fiberoptic bronchoscope approach to placement of a double lumen endobronchial tube and further characterize potential strengths and weaknesses of ...
Luiz Maracaja +6 more
doaj +1 more source
A 29-year-old female (165 cm, 68 kg) with a 4.9 cm × 3.2 cm × 3.5 cm carcinoid tumour in the right intermediate bronchus underwent right bilobectomy. Despite pre-operative computed tomography showing anatomical distortion warranting fibre-optic guidance,
Prateek Maurya +3 more
doaj +1 more source

