Results 161 to 170 of about 83,794 (294)

Transducers Across Scales and Frequencies: A System‐Level Framework for Multiphysics Integration and Co‐Design

open access: yesAdvanced Materials Technologies, EarlyView.
Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu   +8 more
wiley   +1 more source

Respiratory Signal Processing and Analysis Using Flexible Capacitive Sensor Data

open access: yesAdvanced Materials Technologies, EarlyView.
Capacitive pressure sensors based on poly(glycerol sebacate) (PGS) substrates are developed for continuous, non‐invasive respiratory monitoring. Integrated with a signal processing algorithm, they enable accurate tracking of thoracic expansion and retraction.
Bernardo A. Vicente   +3 more
wiley   +1 more source

Non‐Invasive Multidimensional Capacitive Sensing for In Vivo Traumatic Brain Injury Monitoring

open access: yesAdvanced Materials Technologies, EarlyView.
Single‐electrode, multidimensional capacitive sensors noninvasively assess cerebral autoregulation and compliance for traumatic brain injury monitoring. ABSTRACT Traumatic brain injury (TBI) is a major cause of death and disability, but invasive intracranial pressure (ICP) monitoring is risky, and current non‐invasive methods lack the resolution and ...
Shawn Kim   +8 more
wiley   +1 more source

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Mapping of Physiological Signals From Wireless Battery‐Free Implants With Plane‐Wave Ultrasound Imaging

open access: yesAdvanced Materials Technologies, EarlyView.
Combined approach of electromagnetic (Power) and ultrasound (data harvesting) waves is proposed to address the miniaturized ultrasonic implants. Electromagnetic waves trigger the piezoelectric element to generate the acoustic pulse which is modulated by the variations in the sensor's impedance.
Anam Bhatti   +6 more
wiley   +1 more source

Graphene‐Based Wearable Textile Triboelectric Nanogenerators and Biomechanical Sensors

open access: yesAdvanced Materials Technologies, EarlyView.
This study presents a wearable textile‐based triboelectric nanogenerator (T‐TENG) using sprayed graphene enhanced with a PVA adhesion layer. The graphene‐based electrode demonstrates high electrical conductivity and robustness to multiple bends. The fabricated T‐TENG provides stable and efficient output, with strong responsiveness to biomotion.
Hongyang Dang   +4 more
wiley   +1 more source

Galinstan Liquid Metal/Polyurethane Composite as a Multifunctional Stretchable Electrode and Piezoresistive Strain Sensor With Minimal Drift

open access: yesAdvanced Materials Technologies, EarlyView.
Liquid metal additives are processed in elastomer host resulting in highly conductive and stretchable composites. The material functions as a piezoresistive sensor with minimal drift, low stiffness, and enhanced operating range. The film can replace wires to charge a mobile phone at ∼350% strain and monitors bodily motion in real‐time via a portable ...
Patryk Wojciak   +3 more
wiley   +1 more source

3D‐Printed Dynamic Heart Model With Left‐Side Anatomy and Integrated Sensor for Edge‐to‐Edge Repair and Regurgitation Reduction

open access: yesAdvanced Materials Technologies, EarlyView.
This work presents a fully synthetic, 3D‐printed dynamic heart model with left‐side anatomy featuring sutured mitral valve chordae tendineae analogs, embedded actuators for physiologic wall contraction, and customized flexible pressure sensors for the left ventricle.
Alejandro Guillen Obando   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy