Results 1 to 10 of about 147 (112)

Winding Hottest-Spot Temperature Analysis in Dry-Type Transformer Using Numerical Simulation

open access: yesEnergies, 2018
A thermal analysis of a 5 kVA dry-type transformer under linear and non-linear loads conditions is studied in this paper. The main goal here is to calculate the hottest-spot transformer temperature under free convection through the resolution of the heat
Rafael Gonçalves Mafra   +4 more
doaj   +2 more sources

Study on the Electric Field Distribution Characteristics of 66 kV Dry-Type Transformer Based on Functional Graded Material (FGM) Treatment

open access: yesEnergies
Functional graded materials (FGMs) have been successfully applied for improving the insulation performance of insulators, yet there is currently no relevant literature on their application in dry-type transformers.
Xinhan Qiao   +2 more
exaly   +3 more sources

Investigating temperature rise dynamics at hot-spots within dry-Type transformer windings: A comparative analysis across varied loading rates and an extrapolative computational model

open access: yesCase Studies in Thermal Engineering
The dynamic temperature data of a transformer can be utilized to accurately assess its load capability and operational longevity. This paper presents a study on the temperature rise characteristics of hot-spots in dry-type transformer windings and ...
Dongsheng He
exaly   +3 more sources

Method of building transformer acoustic diagnosis database based on multi physical field coupling modeling [PDF]

open access: yesE3S Web of Conferences, 2021
In this paper, a method of building dynamic acoustic diagnosis database of dry-type transformer is proposed. The method is mainly combined with collecting the basic noise of transformer and simulating the acoustic signals of transformer under different ...
Wu Weidong   +5 more
doaj   +1 more source

Deconvolution Beamforming Algorithm Based Abnormal Noise Fault Identification of Dry-Type Transformer

open access: yesZhongguo dianli, 2022
To improve the accuracy of the conventional beamforming location algorithm, the deconvolution beamforming algorithm is proposed for the abnormal noise fault identification of dry-type transformer.
Hailong BAO   +5 more
doaj   +1 more source

A PCA-LSTM-Based Method for Fault Diagnosis and Data Recovery of Dry-Type Transformer Temperature Monitoring Sensor

open access: yesApplied Sciences, 2022
The failure that occurs during the dry-type transformer temperature monitoring sensor working will result in wrong data output, which may cause the monitor and monitoring background to respond incorrectly.
Mingze Zheng   +3 more
doaj   +1 more source

Application of Thermography and Adversarial Reconstruction Anomaly Detection in Power Cast-Resin Transformer

open access: yesSensors, 2022
Dry-type power transformers play a critical role in the power system. Detecting various overheating faults in the running state of the power transformer is necessary to avoid the collapse of the power system.
Kuo-Hao Fanchiang, Cheng-Chien Kuo
doaj   +1 more source

Development of system of on-line monitoring, fault diagnosis and prewarning for insulation of mine-used dry-type transformer

open access: yesGong-kuang zidonghua, 2013
In view of problems that monitoring variable is single and real-time status of insulation of mine-used dry-type transformer cannot be reflected existed in traditional monitoring method of mine-used dry-type transformer because it uses thermocouple to ...
WAN Zhi-qiang   +4 more
doaj   +1 more source

Influence of partial discharge on temperature rise of windings of mine-used flameproof dry-type transformer

open access: yesGong-kuang zidonghua, 2018
In order to analyze influence of air gaps or impurities in insulation layer on temperature rise of windings of mine-used flameproof dry-type transformer, a mine-used 1 000 kVA/10 kV dry-type transformer with continuous winding was selected as research ...
WAN Zhiqiang   +3 more
doaj   +1 more source

Inter-Turn Breakdown Fault Analysis and Winding Structure Optimisation of Winding of Dry-Type Transformers in Wind Farms

open access: yesEnergies, 2023
To address the problem of winding turn-to-turn breakdown faults in 35 kV dry-type transformers in wind farms under overvoltage conditions, this paper establishes a simulation model based on the structural dimensions and material parameters of the ...
Ziheng Pu   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy