Results 1 to 10 of about 147 (112)
Winding Hottest-Spot Temperature Analysis in Dry-Type Transformer Using Numerical Simulation
A thermal analysis of a 5 kVA dry-type transformer under linear and non-linear loads conditions is studied in this paper. The main goal here is to calculate the hottest-spot transformer temperature under free convection through the resolution of the heat
Rafael Gonçalves Mafra +4 more
doaj +2 more sources
Functional graded materials (FGMs) have been successfully applied for improving the insulation performance of insulators, yet there is currently no relevant literature on their application in dry-type transformers.
Xinhan Qiao +2 more
exaly +3 more sources
The dynamic temperature data of a transformer can be utilized to accurately assess its load capability and operational longevity. This paper presents a study on the temperature rise characteristics of hot-spots in dry-type transformer windings and ...
Dongsheng He
exaly +3 more sources
Method of building transformer acoustic diagnosis database based on multi physical field coupling modeling [PDF]
In this paper, a method of building dynamic acoustic diagnosis database of dry-type transformer is proposed. The method is mainly combined with collecting the basic noise of transformer and simulating the acoustic signals of transformer under different ...
Wu Weidong +5 more
doaj +1 more source
To improve the accuracy of the conventional beamforming location algorithm, the deconvolution beamforming algorithm is proposed for the abnormal noise fault identification of dry-type transformer.
Hailong BAO +5 more
doaj +1 more source
The failure that occurs during the dry-type transformer temperature monitoring sensor working will result in wrong data output, which may cause the monitor and monitoring background to respond incorrectly.
Mingze Zheng +3 more
doaj +1 more source
Dry-type power transformers play a critical role in the power system. Detecting various overheating faults in the running state of the power transformer is necessary to avoid the collapse of the power system.
Kuo-Hao Fanchiang, Cheng-Chien Kuo
doaj +1 more source
In view of problems that monitoring variable is single and real-time status of insulation of mine-used dry-type transformer cannot be reflected existed in traditional monitoring method of mine-used dry-type transformer because it uses thermocouple to ...
WAN Zhi-qiang +4 more
doaj +1 more source
In order to analyze influence of air gaps or impurities in insulation layer on temperature rise of windings of mine-used flameproof dry-type transformer, a mine-used 1 000 kVA/10 kV dry-type transformer with continuous winding was selected as research ...
WAN Zhiqiang +3 more
doaj +1 more source
To address the problem of winding turn-to-turn breakdown faults in 35 kV dry-type transformers in wind farms under overvoltage conditions, this paper establishes a simulation model based on the structural dimensions and material parameters of the ...
Ziheng Pu +4 more
doaj +1 more source