Results 261 to 270 of about 83,025 (297)
Some of the next articles are maybe not open access.

Dual active bridge buck-boost converter

2009 IEEE Energy Conversion Congress and Exposition, 2009
A novel isolated bidirectional dc/dc converter suitable for high power applications is proposed. The proposed converter has bidirectional power flow capability with low device ratings for a wide source voltage range. The converter is controlled by varying the duty cycle and phase of the firing pulses, to achieve power flows in both directions and ...
null Sangtaek Han, D. Divan
openaire   +1 more source

PI-fuzzy control of a bidirectional Dual Active Bridge converter

2017 American Control Conference (ACC), 2017
This paper presents a PI-fuzzy controller (PIFC) for an energy storage application based on a 28V Li-ion battery. The battery is fed by an isolated bidirectional Phase-Shifted (PS) Dual Active Bridge (DAB) DC-DC converter (270V/28V, 5kW). The main contribution of this work is the application of the closed-loop fuzzy control system to the DAB converter ...
Said Talbi   +2 more
openaire   +1 more source

Dynamic control of a dual active bridge for bidirectional AC charging

2015 IEEE International Conference on Industrial Technology (ICIT), 2015
The dynamic control of a bidirectional charger based on a dual active bridge (DAB) cascaded with a singlephase grid inverter is the scope of this work. Due to a small dc-link capacitance the power fluctuation of the grid at twice the grid frequency is transferred to the battery.
Martin Rosekeit   +2 more
openaire   +1 more source

Five Level Bidirectional Dual Active Bridge with Symmetrical Configuration

IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society, 2019
Bidirectional Isolated Dual Active Bridge (DAB) plays a vital role in implementation of Solid State Transformer(SST) and DC Bus isolation. Conventionally, it is controlled by Single Phase Shift (SPS) technique, which leads to high $\frac{dv}{dt}$ & high circulating power. It causes high voltage stress and less efficiency of the system.
Dharmendra Yadeo   +4 more
openaire   +1 more source

Three-phase dual active bridge converter design considerations

IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society, 2017
In three-phase dual-active-bridge (DAB) converter, the zero-voltage-switching (ZVS) range, DC capacitor ripple current and converter efficiency are significantly impacted by the selectable system parameters, including transformer turn ratio n, switching frequency f and leakage inductance L k .
Ying Cui, Deqiang Wang, Ali Emadi
openaire   +1 more source

Impact of Electrolyzer on the Operation of a Dual Active Bridge Converter

IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society, 2023
Rohan Shailesh Deshmukh   +4 more
openaire   +1 more source

Dual active bridge converter and its control

Isolated bidirectional DC–DC (IBDC) converters are needed in a wide range of applications including DC microgrids, electric vehicles, and energy storage devices. Among various IBDC topologies, the dual active bridge (DAB) converter is one of the most promising solutions owing to its simple and symmetric structure, the capability of zero-voltage ...
Ping Wang   +3 more
openaire   +2 more sources

Finite Control Set Model Predictive Control for Dual Active Bridge Converter

IEEE Transactions on Industry Applications, 2022
Luca Tarisciotti   +2 more
exaly  