Results 11 to 20 of about 118,554 (256)
Analysis of an explanted dual mobility cup after 21 years, parabolic wear pattern: A case report
Case: A dual mobility cup was implanted in 1983 in a 43-year woman. After 31 years of normal function, we analysed the explanted materials with modern techniques.
Fessy Michel-Henri +2 more
doaj +1 more source
Dual mobility for total hip arthroplasty revision surgery: A systematic review and metanalysis
Introduction: Revision THA (R-THA) is thought to have a higher complication rate if compared to primary THA. Dual Mobility (DM) implants have been designed aiming for achieving greater stability, with good clinical results.
Giacomo Placella +4 more
doaj +1 more source
Introducción Las prótesis trapeciometacarpianas son implantadas desde hace más de 50 años. Entre sus complicaciones, destacan la posibilidad de osteolisis, aflojamiento o luxación.
Álvaro Suárez-López del Amo +4 more
doaj +1 more source
Ilio-psoas impingement with a dual-mobility liner: an original case report and review of literature
Ilio-psoas impingement after total hip arthroplasty often occurs with the metallic rim of the acetabular cup. The main causes are poor cup anteversion or anterior wall defect.
Fessy Michel Henri +5 more
doaj +1 more source
Dual Mobility Cups as the Routine Choice in Total Hip Arthroplasty
Background and Objectives: Total hip arthroplasty (THA) is considered the most successful surgical procedure in orthopedics. However, dislocation remains the main indication for surgical revision.
Ignacio Aguado-Maestro +8 more
doaj +1 more source
Age-related decrements in dual-task performance: Comparison of different mobility and cognitive tasks. A cross sectional study. [PDF]
This cross-sectional study investigated the age-related differences in dual-task performance both in mobility and cognitive tasks and the additive dual-task costs in a sample of older, middle-aged and young adults. 74 older adults (M = 72.63±5.57 years),
Paolo Riccardo Brustio +4 more
doaj +1 more source
Inertial Tracking System for Monitoring Dual Mobility Hip Implants In Vitro
Dual mobility (DM) implants are being increasingly used for total hip arthroplasties due to the additional range of motion and joint stability they afford over more traditional implant types.
Matthew Peter Shuttleworth +7 more
doaj +1 more source
While trust in different types of automated vehicles has been a major focus for researchers and vehicle manufacturers, few studies have explored how people trust automated vehicles that are not cars, nor how their trust may transfer across different ...
Jacob G. Hunter +13 more
doaj +1 more source
Introduction: Total Hip Replacement (THR) in displaced Fracture Neck of Femur (FNOF) is associated with higher dislocation rates. Conventional THR with a large femoral head and anterior approach has reduced the instability, but it remains higher than THR
Agarwala Sanjay +4 more
doaj +1 more source
Dual Polarity Ion Confinement and Mobility Separations [PDF]
Here, we present simulations and describe the initial implementation of a device capable of performing simultaneous ion mobility (IM) separations of positive and negative ions based upon the structures for lossless ion manipulations (SLIM). To achieve dual polarity ion confinement, the DC fields used for lateral confinement in previous SLIM were ...
Isaac K, Attah +7 more
openaire +2 more sources

