Results 21 to 30 of about 203,934 (147)
Analisis Kualitas Minyak Trafo Menggunakan Data Dissolved Gas Analysis dan Water Content
Transformer is a vital equipment in the power system. If the transformer is damage, can cause the electrical distribution to the consumer will be disrupted. Therefore, it needs special maintenance the performance of the transformer to avoid damage.
Abdul Syakur, Fanny Rizka Savitri
doaj +1 more source
Detection of transformer faults avoids the transformer’s undesirable loss from service and ensures utility service continuity. Diagnosis of transformer faults is determined using dissolved gas analysis (DGA).
Sherif S. M. Ghoneim +4 more
doaj +1 more source
Feature Selection and Classification of Transformer Faults Based on Novel Meta-Heuristic Algorithm
Detecting transformer faults is critical to avoid the undesirable loss of transformers from service and ensure utility service continuity. Transformer faults diagnosis can be determined based on dissolved gas analysis (DGA).
El-Sayed M. El-kenawy +7 more
doaj +1 more source
The intent of this work is to understand the influence of low energy discharge electric faults in mineral oil and synthetic esters on liquid degradation and gassing tendency at different aging conditions (based on acidity values).
L. Loiselle, U. Mohan Rao, I. Fofana
doaj +1 more source
Abstract Power transformers are among the most important equipment in a power system. The assessment of the transformer’s condition which is connected to a system is needed to avoid disastrous failures and the subsequent power outages.
null Manisha +4 more
openaire +1 more source
Fault type diagnosis is a very important tool to maintain the continuity of power transformer operation. Dissolved gas analysis (DGA) is one of the most effective and widely used techniques for predicting the power transformer fault types. In this paper,
Ibrahim B. M. Taha +2 more
doaj +1 more source
The current work aims to propose an adequate thermodynamic model, in addition to proposing and evaluating two composite models for the thermal decomposition of insulating mineral oil (IMO), considering that the models based on classical diagnostic ...
A. Manjula +6 more
doaj +1 more source
Diagnosis of OLTC via Duval Triangle Method and Dynamic Current Measurement
AbstractPower transformers studies have shown that the main cause of power transformers failures is the On Load Tap Changer (OLTC). OLTC failure occurs due to the insulation degradation and contacts failure inside it. Other than that, contacts wear influences the OLTC performance and this phenomenon has not been deeply investigated.
Khiar, Mohd Shahril Ahmad +4 more
openaire +1 more source
Diagnosing the type and location of the transformer fault by analyzing the dissolved gas using fuzzy logic [PDF]
There are many methods to diagnose transformer faults, including dissolved gas analysis (DGA), done in two conventional and smart ways. This paper presents a new method based on fuzzy logic and 5 DGA methods (key gas method, Durenberg's ratio method ...
Mohamad Beiranvand, Asghar Akbari Froud
doaj +1 more source
Enhancing the Diagnostic Accuracy of DGA Techniques Based on IEC-TC10 and Related Databases
Investigating and enhancing the accuracy of widespread dissolved gas analysis (DGA) techniques based on IEC-TC10 and related databases was implemented. The current work aimed to help the experts to diagnose the transformers’ faults accurately. The
Osama E. Gouda +2 more
doaj +1 more source