Hand-held dynamic contour tonometry [PDF]
We present a prototype of the hand-held dynamic contour tonometer (HH-DCT) and prospectively compare this HH-DCT with the well-established Perkins applanation tonometer (PAT) and the TonoPenXL (TPXL).In a prospective, single-centre, randomized study, intraocular pressure (IOP) readings were taken in random order using HH-DCT, PAT and TPXL tonometers ...
Pascal B. Knecht+6 more
openalex +4 more sources
Correlation of intraocular pressure measured with goldmann and dynamic contour tonometry in normal and glaucomatous eyes. [PDF]
Realini T, Weinreb RN, Hobbs G.
europepmc +3 more sources
Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice [PDF]
Abstract.Purpose: To compare intraocular pressure (IOP) readings taken using dynamic contour tonometry (DCT) with IOP readings taken with Goldmann applanation tonometry (GAT) in eyes with glaucoma or ocular hypertension.Methods: The present study included 100 eyes in 100 patients with glaucoma or ocular hypertension. After pachymetry DCT and GAT were
Ioannis Halkiadakis+9 more
openalex +4 more sources
Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes [PDF]
To compare the measurements of intraocular pressure (IOP) with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in healthy and glaucomatous eyes and to evaluate the influence of corneal thickness (CCT), corneal curvature (CC), axial length (AL), and age on these tonometric alternatives.Three hundred eyes of 100 healthy subjects,
Piero Ceruti+3 more
openalex +5 more sources
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry [PDF]
Purpose: To compare dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) and investigate the influence of central corneal thickness (CCT) onintraocular pressure. Methods: In a prospective study of 165 eyes with glaucoma (135 eyes), glaucoma suspect (14 eyes), and ocular hypertension (16 eyes), intraocularpressure was measured with ...
Jang Won Seo+2 more
openalex +3 more sources
Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry [PDF]
To compare the intraocular pressure (IOP) measurements obtained using the Pascal dynamic contour tonometer (PDCT) with the standard Goldmann applanation tonometer (GAT) and to correlate these with central corneal thickness (CCT) in patients with normal corneas.A prospective, masked, comparative case series of 116 eyes from patients attending a glaucoma
Judy Y.F. Ku+4 more
openalex +5 more sources
Purpose: The accuracy of Goldmann applanation tonometry (GAT) has been shown to depend on several biomechanical properties of the cornea. Newer tonometry devices (e.g., the Dynamic Contour Tonometer PASCAL? [DCT] and the Tono-Pen?
Matthias Neuburger+8 more
openalex +3 more sources
Comparison of dynamic contour tonometry and noncontact tonometry in ocular hypertension and glaucoma [PDF]
To assess the agreement in the measurement of intraocular pressure obtained by dynamic contour tonometer (DCT) and noncontact tonometer (NCT) in patients with glaucoma and ocular hypertension, to investigate the effect of corneal thickness on pressure readings by both instruments, and to assess the reproducibility of dynamic contour tonometer.NCT and ...
Mesut Erdurmuş+3 more
openalex +4 more sources
Review on Dynamic Contour Tonometry and Ocular Pulse Amplitude [PDF]
Intraocular pressure (IOP) measurement is the cornerstone of the management of glaucoma patients. The gold standard for assessing IOP is Goldmann applanation tonometry (GAT). Recently, the dynamic contour tonometer (DCT) has become available. While both devices provide reliable IOP measurements, the results are not interchangeable.
K. Willekens+6 more
semanticscholar +3 more sources
Background: Until now, no direct relationship has been established between the target pressure and particular corneal thickness for measurements with different types of tonometers.
Dmitriev S. K.+3 more
doaj +1 more source