Comparison of correction formulas for intraocular pressure measured by Goldmann tonometer following various refractive surgeries (FS-LASIK, SMILE, tPRK) [PDF]

open access: yesFrontiers in Bioengineering and Biotechnology
ObjectiveThis study aims to compare different intraocular pressure (IOP) correction formulas in post-refractive surgery patients who underwent Femtosecond Laser-Assisted In Situ Keratomileusis (FS-LASIK), Small Incision Lenticule Extraction (SMILE), and ...
Jie Tong   +35 more
doaj   +2 more sources

Hand-held dynamic contour tonometry [PDF]

open access: yesActa Ophthalmologica, 2011
Purpose: We present a prototype of the hand-held dynamic contour tonometer (HH-DCT) and prospectively compare this HH-DCT with the well-established Perkins applanation tonometer (PAT) and the TonoPenXL (TPXL). Methods: In a prospective, single-centre, randomized study, intraocular pressure (IOP) readings were taken in random order using HH-DCT, PAT and
Knecht, P B   +6 more
openaire   +3 more sources

Relationships between target intraocular pressure and central corneal thickness in stabilized and non-stabilized glaucoma patients

open access: yesJournal of Ophthalmology, 2021
Background: Until now, no direct relationship has been established between the target pressure and particular corneal thickness for measurements with different types of tonometers.
Dmitriev S. K.   +3 more
doaj   +1 more source

Dynamic Contour Tonometry [PDF]

open access: yesArchives of Ophthalmology, 2004
To compare intraocular pressure measurements obtained by recently introduced dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT), pneumatonometry (PTG), and intracameral manometry in human cadaver eyes.Sixteen freshly enucleated human cadaver eyes were deepithelialized and dehydrated with dextran.
Christoph, Kniestedt   +2 more
openaire   +2 more sources

Comparison of IOP obtained in different kind of eyes with contact and no contact tonometers

open access: yesOman Journal of Ophthalmology, 2022
BACKGROUND: The aim of this study is to analyze and compare the intraocular pressure (IOP) values measured in three different kinds of participants such as healthy subjects (HS), keratoconus patients (KP), and those who underwent myopic photorefractive ...
Sandro Sbordone   +6 more
doaj   +1 more source

Correlation between central corneal thickness and intraocular pressure in various age groups [PDF]

open access: yesSrpski Arhiv za Celokupno Lekarstvo, 2010
Introduction The Pascal Dynamic Contour Tonometer (DCT) is an ophthalmic investigational device which directly calculates the dynamic pulsatile fluctuations in intraocular pressure (IOP) using a piezoelectric pressure sensor embedded in the devices tip ...
Marjanović Ivan   +4 more
doaj   +1 more source

Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry

open access: yesInvestigative Opthalmology & Visual Science, 2004
The dynamic contour tonometer (DCT; Pascal tonometer) is a novel tonometer designed to measure intraocular pressure (IOP) independent of corneal properties. The purpose of this study was a comparison of the DCT with the Goldmann applanation tonometer (GAT) with respect to mean of IOP readings, the influence of ocular structural factors on IOP readings,
Kaufmann C, Bachmann LM, Thiel MA
openaire   +3 more sources

Intraocular Pressure Measurement after Penetrating Keratoplasty

open access: yesDiagnostics, 2022
Assessing the intraocular pressure is a difficult but crucial task in the follow-up of patients that have undergone penetrating keratoplasty. Early recognition of elevated intraocular pressure and/or glaucoma and establishment of the appropriate ...
Otilia-Maria Dumitrescu   +3 more
doaj   +1 more source