Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness [PDF]
AIM: To determine the effects of peripheral corneal thickness (PCT) on dynamic contour tonometry(DCT) and Goldmann applanation tonometry (GAT). METHODS: A cross-sectional study.
Federico Saenz-Frances +8 more
doaj +1 more source
Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management. [PDF]
A soft contact lens sensor enables continuous, noninvasive monitoring of nocturnal intraocular pressure (IOP) under closed‐eye sleep conditions. By integrating a highly compliant inductive–capacitive circuit onto a commercial lens, the device achieves record sensitivity and stable performance.
Dai Y +19 more
europepmc +2 more sources
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry
Purpose: To compare dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) and investigate the influence of central corneal thickness (CCT) onintraocular pressure. Methods: In a prospective study of 165 eyes with glaucoma (135 eyes), glaucoma suspect (14 eyes), and ocular hypertension (16 eyes), intraocularpressure was measured with ...
Jang Won Seo +2 more
openaire +1 more source
Comparison of Goldmann applanation, non-contact, dynamic contour and tonopen tonometry measurements in healthy and glaucomatous eyes, and effect of central corneal thickness on the measurement results [PDF]
Aim To compare the correlation of intraocular pressure (IOP) measurements obtained using Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), dynamic contour tonometer (DCT) and tono-pen (TP) in glaucomatous and healthy eyes, and to ...
Aydın Yildiz, Tekin Yasar
doaj +1 more source
Impact of corneal parameters on intraocular pressure measurements in different tonometry methods [PDF]
AIM: To evaluate the impact of central corneal thickness (CCT) and corneal curvature on intraocular pressure (IOP) measurements performed by three different tonometers.
Aleksandra Zakrzewska +2 more
doaj +1 more source
This review organizes flexible wearable electronics for cardiovascular monitoring into four interconnected information layers: surface electrophysiology, hemodynamic sensing, vascular imaging, and biofluid biomarker analysis. This framework clarifies how electrical rhythm, vascular loading, structural and flow‐related features, and biochemical states ...
Qiao Chen +5 more
wiley +1 more source
The Effects of Trabeculectomy on Ocular Pulse Amplitude in Patients with Glaucoma
INTRODUCTION[|]This study aimed to investigate whether trabeculectomy and its intraocular pressure (IOP)-lowering effect have an effect on ocular pulse amplitude (OPA) in glaucoma patients.[¤]METHODS[|]Thirty-five consecutive patients with glaucoma (70 ...
Yalcin Karakucuk
doaj +1 more source
Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry
OBJECTIVES: To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA) measurements that are independent of corneal thickness and curvature, and to assess variables of observer agreement.
Robert, Yves C +3 more
core +1 more source
Abstract Purpose To evaluate bleb morphology longitudinally using sonography following glaucoma drainage device (GDD) surgery. Methods Prospective observational cohort study conducted from January 2022 to March 2024, with follow‐up up to 12 months postoperatively. Bleb morphology, including superior and inferior bleb height, transverse and longitudinal
Constance Liegl +9 more
wiley +1 more source
Australian and New Zealand Glaucoma Society (ANZGS) Consensus on Interventional Glaucoma
ABSTRACT Background Traditional reactive ‘wait and see’ approaches in glaucoma management often result in unacceptable rates of permanent vision loss. This consensus defines a proactive ‘interventional glaucoma’ framework tailored for the Australian and New Zealand healthcare context. Methods A modified Delphi consensus process was utilised, consisting
Graham A. Lee +12 more
wiley +1 more source