Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus [PDF]

open access: yesJournal of Optometry, 2017
Purpose: To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal ...
Fatih Özcura   +3 more
doaj   +9 more sources

Dynamic contour tonometry in asymmetric glaucoma patients [PDF]

open access: yesClinical Ophthalmology, 2012
Emilio Rintaro Suzuki Jr1, Cibele Lima Belico Suzuki1, Danielle Carlier1, Daniele Penha1, Marta dos Anjos Rodrigues Parchen1, Wagner Duarte Batista1, Joao Agostini Netto21Glaucoma Service, 2Department of Ophthalmology, Santa Casa de Belo Horizonte, MG ...
Parchen MAR   +6 more
doaj   +9 more sources

Comparison of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes [PDF]

open access: yesInternational Journal of Ophthalmology, 2015
AIM: To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in normal and glaucomatous eyes and investigate the effects of central corneal ...
Fatih Özcura   +4 more
doaj   +9 more sources

Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]

open access: yesScientific Reports, 2022
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo   +5 more
doaj   +6 more sources

Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy [PDF]

open access: yesJournal of Ophthalmology, 2010
Background. To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) following trabeculectomy. Methods. Thirty eight glaucomatous eyes with a history of trabeculectomy (Trabeculectomy group, TG), 20 eyes ...
Efstathios T. Detorakis   +3 more
doaj   +6 more sources

Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]

open access: yesTherapeutic Advances in Ophthalmology, 2020
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis   +5 more
doaj   +3 more sources

The influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: An ecological meta-analysis [PDF]

open access: yesIndian Journal of Ophthalmology, 2023
Purpose: A meta-analysis found that including atmospheric pressure as altitude in generalized linear models reveals higher differences between Goldmann tonometry and Pascal dynamic contour tonometry at higher altitudes, with the difference increasing in ...
Oscar Albis-Donado   +3 more
doaj   +3 more sources

Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature [PDF]

open access: yesClinical Ophthalmology, 2016
Konstantinos Andreanos, Chryssanthi Koutsandrea, Dimitris Papaconstantinou, Andreas Diagourtas, Andreas Kotoulas, Panagiotis Dimitrakas, Marilita M Moschos First Department of Ophthalmology, University of Athens, “G.
Andreanos K   +6 more
doaj   +5 more sources

Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK [PDF]

open access: yesClinical Ophthalmology, 2012
Gabi Shemesh,* Uri Soiberman,* Shimon KurtzDepartment of Ophthalmology, Tel Aviv Medical Center, and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel*These two authors contributed equally to this workBackground and methods: Myopic ...
Shemesh G, Soiberman U, Kurtz S
doaj   +3 more sources

The Effect of Corneal Thickness, Densitometry and Curvature on Intraocular Pressure Measurements Obtained by Applanation, Rebound and Dynamic Contour Tonometry [PDF]

open access: yesVision, 2020
Evaluate the effect of corneal thickness, densitometry and curvature on intraocular pressure (IOP) measurements obtained by Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), rebound tonometry (RT), and dynamic contour tonometry (DCT).
Marco Antonio de Castro Olyntho Junior   +3 more
doaj   +3 more sources