Results 211 to 220 of about 3,218 (250)
Some of the next articles are maybe not open access.

Оsteogenesis and rehabilitation in pertrochanteric fractures with dynamic hip screw- DHS

Archives of Public Health, 2017
Цел на трудот е да се направи споредба на ефектите од два физикални модалитети, магне- тотерапијата наспроти терапијата со интерферентни струи при физикалното  лекување и ре- хабилитација на пациенти со оперативно решена пертрохантерна фрактура на фемур со ДХС и да укаже на влијанието врз остеогенезата.
Митревска (Mitrevska), Билјана (Biljana)   +4 more
openaire   +1 more source

Dynamic hip screw (DHS) results in intertrochanteric fractures

2014
Sağlık Bakanlığı Haseki Hastanesi Ortopedi ve Travmatoloji Kliniği'nde 1.1.1986-31.3.1989 tarihleri arasında 96 hasta intertrokanterik kırık tanısı ile tedavi edildi. Bunlardan 63'üne DHS uygulandı. Olguların 29'u (%46) kadın, 34'ü (%54) erkekti. Yaş ortalaması 64.3 idi.
KORKMAZ, Ahmet   +4 more
openaire   +1 more source

Dynamic hip screw: does side make a difference? Effects of clockwise torque on the right and left DHS

Injury, 2002
A study was performed to assess the effect of clockwise rotational torque onto the fracture configuration in unstable intertrochanteric fractures. The premise is that rotational torque in the sagittal plane imparted during screw insertion can lead to a potentially unstable construct in LEFT-sided DHS fixations when compared to the RIGHT-sided ones ...
Humayon Pervez, Martyn J Parker
openaire   +2 more sources

[Analysis of the treatment failures for intertrochanteric fractures with dynamic hip screw (DHS)].

Zhongguo gu shang = China journal of orthopaedics and traumatology, 2010
To analyze the reasons and related factors of failures in the treatment of intertrochanteric fracture with dynamic hip screw (DHS) and to increase the therapeutic level of intertrochanteric fracture.All the 78 cases of intertrochanteric fractures were treated with dynamic hip screws from Dec. 1998 to Dec.
Zhong, Zhou   +5 more
openaire   +1 more source

[DHS (Dynamic Hip Screw) osteosynthesis in an atypical situation].

Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca, 2003
The author describes a spiral fracture of the distal femur with a fragmented zone that occurred in the place of the distal end of a splint applied because of the previous treatment of a subtrochanteric fractures by osteosynthesis. Atypical approach including a DHS implant was used to treat the spiral fracture.
openaire   +1 more source

Mechanical failure of Dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur.

The Medical journal of Malaysia, 2003
We studied 60 intertrochanteric fractures of the femur fixed with Dynamic Hip Screw (DHS). There were 10 cases (16.7%) with cutting-out of device through femoral head and neck. Stable fracture pattern, postero-inferior and central position of screw in the femoral neck and head produced high percentage of good result, whereas anterior or superior ...
S, Nordin, O, Zulkifli, W I, Faisham
openaire   +1 more source

[The DHS (dynamic hip screw) buttress plate in the management of unstable proximal femoral fractures].

Schweizerische medizinische Wochenschrift, 1993
The DHS-implant system is a technically simple and widely used operative treatment modality for pertrochanteric fractures of the femur. In unstable 4-part fractures rotation of the head and neck fragment around the lag screw and significant impaction might lead to lateralisation of the greater trochanter and therefore to marked shortening.
R, Babst   +6 more
openaire   +1 more source

A Study Comparing Cannulated Cancellous Screws (CCS) versus Dynamic Hip Screw (DHS) in Femoral Neck Fractures in Productive Age Group

Aim: The aim of the present study was comparing cannulated cancellous screws (CCS) versus dynamic hip screw(DHS) in femoral neck fractures in productive age group.Methods: This study was conducted in the Department of Orthopaedics, SKMCH, Muzaffarpur, Bihar, India.
Anand Kumar   +2 more
openaire   +1 more source

Dynamic hip screw: does side make a difference? Effects of clockwise torque on right and left DHS.

Injury, 2001
A study was performed to assess the effect of clockwise rotational torque onto the fracture configuration in unstable intertrochanteric fractures. The premise is that rotational torque in the sagittal plane imparted during screw insertion can lead to a potentially unstable construct in LEFT-sided DHS fixations when compared to the RIGHT-sided ones ...
R, Mohan, R, Karthikeyan, S V, Sonanis
openaire   +1 more source

Integrative oncology: Addressing the global challenges of cancer prevention and treatment

Ca-A Cancer Journal for Clinicians, 2022
Jun J Mao,, Msce   +2 more
exaly  

Home - About - Disclaimer - Privacy