Results 11 to 20 of about 8,900 (202)
Incremental ECAP of Plates [PDF]
Batch severe plastic deformation (SPD) processes are mainly used for laboratory purposes. More industrially oriented are continuous processes among which the new SPD process of Incremental Equal Channel Angular Pressing (I-ECAP) is an attractive option.
Olejnik, L. +2 more
core +14 more sources
New process configurations for ECAP
ECAP is a very mature SPD process, which seems not to leave many options for further development.
Rosochowski, Andrzej, Olejnik, Lech
core +5 more sources
Texture of ECAP processed Aluminum [PDF]
In this thesis the studied material was pure aluminum that was processed by Equal Channel Angular Pressing (ECAP). The main research objectives were to determine the texture development of aluminum during ECAP processing, and to study the changes in texture after additional high rate axial compression deformation.
Bozic, Martina
openaire +2 more sources
Abstract Objectives The study aimed to assess the feasibility of recording electrically evoked compound action potentials (ECAPs) from the rat spinal cord. To achieve this, we characterized electrophysiological responses of dorsal column (DC) axons from electrical stimulation and quantified the relationship between ECAP and motor thresholds (ECAPTs and
Birte Elisabeth Dietz +3 more
wiley +1 more source
A Clinical Feasibility Study of Spinal Evoked Compound Action Potential Estimation Methods
Abstract Objectives Spinal cord stimulation (SCS) is a treatment for chronic neuropathic pain. Recently, SCS has been enhanced further with evoked compound action potential (ECAP) sensing. Characteristics of the ECAP, if appropriately isolated from concurrent stimulation artifact (SA), may be used to control, and aid in the programming of, SCS systems.
Krishnan Chakravarthy +6 more
wiley +1 more source
Complaints and Diagnoses of Emergency Department Patients in the Netherlands: A Comparative Study of Integrated Primary and Emergency Care. [PDF]
In the Netherlands, an increasing number of emergency departments (EDs) and general practitioner cooperatives collaborate by creating one Emergency-Care-Access-Point (ECAP). This has resulted in fewer patients at ECAP EDs. The objective of this study was
Wendy A M H Thijssen +6 more
doaj +1 more source
Noise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images
Stephan Schreiner +11 more
doaj +1 more source
Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array [PDF]
Background: The standard electrode array for the MED-EL MAESTRO cochlear implant system is 31 mm in length which allows an insertion angle of approximately 720°.
Zierhofer Clemens +25 more
core +1 more source
X-ray phase-contrast imaging is a promising method for medical imaging and non-destructive testing. Information about the attenuation, small-angle scattering and phase-shifting properties of an object can be gained simultaneously in three image ...
Maria Seifert +8 more
doaj +1 more source
The most effective metal manufacturing process is double pressing, which is capable of bending metal. The bending of the metal will cause a reaction that can improve its mechanical properties. In the book Al-Jamahir fi ma`rifat al-Jawahir there are three
Agus Pramono
doaj +1 more source

