Results 141 to 150 of about 67,008 (260)
ABSTRACT Background Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated ...
Joseph M. O'Brien +13 more
wiley +1 more source
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos +6 more
wiley +1 more source
In and Out: Eccentricity in Britain
International audienceThe aim of In and Out: Eccentricity in Britain is twofold: first, to provide an overview of the critical history of eccentricity, and secondly to conceptualise a notion that is often presented as a defining feature of the English ...
Mellet, Laurent, Aymes-Stokes, Sophie
core +1 more source
Automated Process Optimization in a Novel Triple Shaft Mixer with Adaptive Mixing Modes
A novel multi‐purpose mixer with adjustable blade angle and a coaxial stirrer is developed, providing three degrees of freedom. An optimization strategy is integrated to autonomously identify optimal operating conditions through automated tests. The current draw of the main stirrer serves as the optimization criterion, while stirrer speeds, directions,
B. Schwarz, H. Kniele, J. A. Lindner
wiley +1 more source
In the ENPRO REUNION project, a manufacturer‐independent modular plant concept was demonstrated by commissioning a pilot plant that integrated modules from different vendors and by expanding the module pool to include extraction and crystallization units.
Laura Marsollek +8 more
wiley +1 more source
Assembly and Maintenance of Myofibrils in the Heart
ABSTRACT The assembly of actin and myosin to the paracrystalline arrangement of myofibrils in striated muscle, that is, heart and skeletal, has puzzled many a cell biologist. Different models, based on cultured cardiomyocytes, were proposed for the last 30 years to explain the sequence of events.
Elisabeth Ehler
wiley +1 more source
Mapping human visual contrast sensitivity and vision loss across the visual field with model-based fMRI. [PDF]
Chow-Wing-Bom HT +7 more
europepmc +1 more source
ABSTRACT We here describe mouse models with complementary homozygous Svil mutations. In skeletal muscle, Svil‐Mut mice express the Svil‐encoded N‐terminus fused to the βgal‐neo gene‐trap tag and lack the highly conserved archvillin C‐terminus; Svil‐KO mice lack expression of all known Svil‐encoded proteins; and Svil‐LoxP mice contain loxP sites for ...
Tara C. Smith +9 more
wiley +1 more source
Disrupted thalamic functional hierarchy on resting-state fMRI in idiopathic generalized epilepsy. [PDF]
Chen J +11 more
europepmc +1 more source

