Results 151 to 160 of about 9,178 (186)
AbstractBackground:Therapeutic drug monitoring (TDM) of sirolimus is essential in transplant recipients. We evaluated the performance of a new electrochemiluminescence immunoassay (ECLIA) for measuring sirolimus concentrations in whole blood at five European laboratories.Methods:Study assessments included repeatability, intermediate precision and ...
Veronique Stove +2 more
exaly +5 more sources
The Application of Electrochemiluminescence Immunoassay (ECLIA) in the Detection of HIV Infectious Markers in Blood Screening [PDF]
Objective: This study aimed to analyze ELISA, ECLIA, and Western blot (WB) confirmatory test results for HIV-reactive blood donors, compare ECLIA with fourth-generation ELISA reagents, assess the feasibility of using ECLIA for HIV screening, and provide statistical evidence supporting its adoption in blood collection and supply institutions ...
He-Wei, Song +3 more
exaly +4 more sources
Coronavirus disease 2019 (COVID-19) has a wide spectrum of clinical severity. A cytokine storm is associated with COVID-19 severity. Of these, IL-6 is significantly associated with higher mortality and is also a marker for predicting disease prognosis.
Giovanni Cappelli +2 more
exaly +5 more sources
The Analyzation and Clinical Evaluation of ECLIA and CMIA in the Detection of Treponema pallidum
To evaluate the clinical application value of electrochemiluminescence immunoassay analyzer (ECLIA) and chemiluminescent magnetic microparticle immunoassay (CMIA) in the detection of Treponema pallidum (TP).A total of 1225 patients in Peking University Third Hospital was enrolled from June 2014 to October 2014. ECLIA and CMIA were applied to detect the
Liyan Cui, Jiansuo Zhou
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Clinical Biochemistry, 2018
To determine salivary cortisol reference intervals in a healthy adult population, at 6 different time points during a 24-hour (h) period.In a prospective study, salivary cortisol concentrations were measured upon waking, one-hour post-waking and at specific times of the day: at 12 h00, 16 h00, 20 h00 and midnight. Samples were analyzed by the first and
Jean Dubé +2 more
exaly +3 more sources
To determine salivary cortisol reference intervals in a healthy adult population, at 6 different time points during a 24-hour (h) period.In a prospective study, salivary cortisol concentrations were measured upon waking, one-hour post-waking and at specific times of the day: at 12 h00, 16 h00, 20 h00 and midnight. Samples were analyzed by the first and
Jean Dubé +2 more
exaly +3 more sources
Is ECLIA Serum Cortisol Concentration Measurement, an Accurate Indicator of Pain Severity in Dogs With Locomotor Pain? [PDF]
The purpose of determining serum cortisol level is to reflect the activity of stress axis, ethological alterations, acute and chronic pain, life quality, or psychogenic stress. Although it is stated that stress can produce a measurable influence on the cortisol level, a certified value of this pain biomarker in dogs was not generally accepted yet. This
Romeo Teodor Cristina +2 more
exaly +5 more sources
New Quantitative Electrochemiluminescence Method (ECLIA) for Interleukin-6 (IL-6) Measurement
Clinical Chemistry and Laboratory Medicine, 2010Abstract Background: A new interleukin-6 (IL-6) electrochemiluminescent immunoassay (ECLIA, Roche Diagnostics) was evaluated and compared to a previous semiquantitative immunoassay (Milenia Biotec). Reference ranges for cord blood plasma were also calculated.
Belén Prieto
exaly +3 more sources
Introduction: Carcinoembryonic antigen (CEA) is used for monitoring of disease progression and treatment response in cancer patients. Our aim was to compare the performance of chemiluminescent microparticle immunoassay (CMIA) with electrochemiluminescence immunoassay (ECLIA) for CEA. Methods: A total of 115 samples were collected during routine ...
Nafija Serdarevic
exaly +4 more sources
European Journal of Clinical Microbiology and Infectious Diseases, 2018
In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera
Aref Teimouri +2 more
exaly +3 more sources
In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera
Aref Teimouri +2 more
exaly +3 more sources