Results 111 to 120 of about 209 (193)

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID‐Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI)

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To implement and evaluate an efficient method for absolute temperature measurement using a gradient echo implementation of the echo planar spectroscopic imaging (EPSI) sequence. Methods The gradient echo EPSI sequence (GREPSI) utilizes an oscillating readout gradient together with continuous signal readout after slab selective ...
Dennis L. Parker   +5 more
wiley   +1 more source

A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To present a novel, nonlinear subspace modeling and joint k–q‐space reconstruction technique for high‐resolution, multi‐band, multi‐shell diffusion‐weighted imaging (DWI). Methods High b‐value (> 1000 s/mm2), high resolution DWI has the drawback of generally low signal‐to‐noise ratios (SNRs).
Julius Glaser   +4 more
wiley   +1 more source

Comparative Systematic Analysis of Gray Matter Biophysical Models on a Public Dataset

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Biophysical models of diffusion tailored to characterize gray matter (GM) microstructure are gaining traction in the neuroimaging community. NEXI, SMEX, SANDI, and SANDIX represent recent efforts to account for different microstructural features, such as soma contributions and inter‐compartment exchange, in the diffusion MRI (dMRI ...
Santiago Mezzano   +6 more
wiley   +1 more source

Generative MR Multitasking With Complex‐Harmonic Cardiac Encoding: Bridging the Gap Between Gated Imaging and Real‐Time Imaging

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a unified image reconstruction framework that bridges real‐time and gated cardiac MRI, including quantitative MRI. Methods We introduce generative multitasking, which learns subject‐ and dataset‐specific implicit neural temporal bases from sequence timings and an interpretable latent space for cardiac and respiratory motion.
Xinguo Fang, Anthony G. Christodoulou
wiley   +1 more source

Combined ADC and T2 Mapping in the Prostate Using a 3D Reduced FOV Sequence

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a 3D reduced FOV sequence for combined ADC and T2 mapping in the prostate in a single scan. Methods A 3D ADC and T2 mapping reduced FOV acquisition is enabled using T2 and diffusion preparation modules with slab‐selective tip‐down pulses and magnitude stabilizer gradients.
Yannik Ott   +8 more
wiley   +1 more source

Flow 2.0: A Standardized Toolbox for Real‐Time Phase‐Contrast MRI of Neurofluid Dynamics

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Real‐time phase‐contrast MRI (RT‐PC) enables continuous quantification of physiological flow dynamics across multiple temporal frequencies, but its broader application is limited by complex and fragmented post‐processing workflows.
Pan Liu, Olivier Balédent
wiley   +1 more source

Comparative Performance Analysis of an Open Source Motion‐Compensated Cardiac Diffusion Sequence Across Different MRI Systems and Gradient Strengths—A Pilot Study

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers.
Eric Arbes   +7 more
wiley   +1 more source

Human In Vivo Validation of Frequency‐Dependent QTI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose The aim of this work is to investigate if q‐space trajectory imaging (QTI) waveforms can be designed to probe QTI metrics at a single centroid frequency under realistic experimental conditions for in vivo human brain imaging. Methods Realistic diffusion encoding waveforms based on double‐rotation gradient waveform and magic‐angle ...
Svenja Niesen   +3 more
wiley   +1 more source

Improving Fetal Single‐Voxel Magnetic Resonance Spectroscopy With Spectral Registration

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate whether spectral registration improves spectral quality and quantification reliability in in vivo single‐voxel fetal brain MRS: Methods Fourteen fetal PRESS datasets were acquired at 3 T at TE = 35 ms and TE = 135 ms. Raw data were processed with eddy‐current phase correction, coil combination, spectral registration, and ...
Andres Saucedo   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy