Results 61 to 70 of about 1,765 (182)
Aim: The aim of this study was to compare the Exradin W2 scintillator, PTW microDiamond, IBA Razor Nano, and IBA Razor chamber detectors for small-field dose measurements and validate the measured data against the EGSnrc user code and observe the ...
Nazia Parveen +4 more
doaj +1 more source
Abstract Background Clinical dosimetry for kV X‐ray radiotherapy beams requires calibrated ionization chambers. When the clinical field size differs from the field size used for chamber calibration, in‐air measurements result in a different magnitude of scatter from the detector stem or body housing affecting the sensitive volume.
Fayz Kadeer +2 more
wiley +1 more source
Three widely used Monte Carlo systems were benchmarked against recently published measurements of the angular distribution of 13 MeV and 20 MeV electrons scattered from foils of different atomic numbers and thicknesses. Source and geometry were simulated
Sempau, Josep +5 more
core +1 more source
Purpose: Monte Carlo simulation was carried out for a 6 MV flattening filter-free (FFF) indigenously developed linear accelerator (linac) using the BEAMnrc user-code of the EGSnrc code system. The model was benchmarked against the measurements.
Bibekananda Mishra +4 more
doaj +1 more source
Abstract Background An ionization chamber and electrometer allow measurement of the absorbed dose to water. A sensitivity comparison between electrometers is essential for quality control, and an efficient method is available to accurately measure the electrometer sensitivity coefficient without using a linear accelerator (linac).
Hayato Tsuno +7 more
wiley +1 more source
The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices.
Perrot, Y. +9 more
core +1 more source
Monte Carlo Modelling of an Orthovoltage X-ray System Using Multiple Applications in EGSnrc
Biodosimetry relies on calibration curves to convert biological damage induced by ionizing radiation to an absorbed dose. Health Canada generates these curves by irradiating biological samples with X-rays, though exposures scenarios could consist of ...
Gunasekara, Dinindu Bawantha
core +1 more source
Quality control of radiotherapy treatment plans with electrons
In this work the quality of the treatment planning generated by EclipseÒ commercial treatment planning system for electron beams of energy 9 and 20 MeV was verified and their accuracy in the calculation of dose distributions for several clinical ...
Luciana Tourinho Campos +3 more
doaj +1 more source
Simulasi teknik radiasi volumetric modulated arc therapy (VMAT) berdasarkan data Dynamic log (Dynalog) menggunakan metode Monte Carlo-EGSnrc [PDF]
INDONESIA: Pada radioterapi modern khususnya External Beam Radiation Therapy (EBRT) menggunakan Linear Accelerator (linac) sebelum dilakukan treatment, perhitungan dosis Analytical Anisotropic Algoritm (AAA) terlebih dahulu dilakukan. Selain itu untuk
Nitasari, Arrum
core +1 more source
A novel system for micron‐scale analysis of energy deposition and response to low‐dose radiation
Abstract Background Micrometer‐scale evaluation of energy deposition is important for radiation protection and therapy as well as for advancing knowledge of responses to radiation in materials and biological systems. Due to the stochastic nature of radiation interactions, there is significant variation in energy deposition in micrometer‐sized targets ...
Prarthana Pasricha +11 more
wiley +1 more source