Results 71 to 80 of about 4,632 (208)

Validação de um modelo computacional de acelerador linear VARIAN CLINAC 2100 utilizando o código EGSnrc para utilização em dosimetria de pequenos campos.

open access: yesBrazilian Journal of Radiation Sciences, 2018
Neste trabalho foi empregado o Método de Monte Carlo para a simulação de campos clínicos de radioterapia que serão posteriormente utilizados para a calibração de pequenos campos de radiocirurgia. O código de transporte de radiação utilizado foi o EGSnrc
Reginaldo Gonçalves Leão Jr   +4 more
doaj   +1 more source

Comparison and validation of multiple detectors against monte carlo simulation for the use of small-field dosimetry

open access: yesJournal of Medical Physics, 2022
Aim: The aim of this study was to compare the Exradin W2 scintillator, PTW microDiamond, IBA Razor Nano, and IBA Razor chamber detectors for small-field dose measurements and validate the measured data against the EGSnrc user code and observe the ...
Nazia Parveen   +4 more
doaj   +1 more source

Accurate,robust and harmonized implementation of morpho-functional imaging in treatment planning for personalized radiotherapy [PDF]

open access: yes, 2019
In this work we present a methodology able to use harmonized PET/CT imaging in dose painting by number (DPBN) approach by means of a robust and accurate treatment planning system.
Baeza, José Antonio   +8 more
core   +2 more sources

Uso de Métodos Monte Carlo na Modelagem de Fontes Radioativas Naturais

open access: yesBrazilian Journal of Radiation Sciences, 2015
Exist, in Brazil and in the world, different places with high levels of ambient radiation, mainly due to the presence of primordial radionuclides, exposing populations to risks that can not be neglected.
Gutemberg Luiz Sales Claudino   +4 more
doaj   +1 more source

Simulation, visualization and dosimetric validation of scatter radiation distribution under fluoroscopy settings [PDF]

open access: yes, 2015
2015-2016 > Academic research: refereed > Refereed conference paperVersion of ...
Chan, LWC   +4 more
core   +1 more source

A geometrical model for the Monte Carlo simulation of the TrueBeam linac [PDF]

open access: yes, 2015
Monte Carlo (MC) simulation of linacs depends on the accurate geometrical description of the head. The geometry of the Varian TrueBeam (TB) linac is not available to researchers. Instead, the company distributes phase-space files (PSFs) of the flattening-
Brualla, Lorenzo   +5 more
core   +3 more sources

Commissioning and verification of a 3D Monte Carlo independent calculation software for O‐ring linac systems

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 1, January 2026.
Abstract Background O‐ring linac systems improve radiotherapy efficiency but require rigorous pretreatment verification due to increased delivery uncertainty in IMRT/VMAT. Existing methods face limitations: measurement‐based approaches incur setup errors, while calculation‐based methods (e.g., Monte Carlo) need machine‐specific validation per AAPM TG ...
Xiangyin Meng   +9 more
wiley   +1 more source

Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport

open access: yes, 2010
Monte Carlo simulation is the most accurate method for absorbed dose calculations in radiotherapy. Its efficiency still requires improvement for routine clinical applications, especially for online adaptive radiotherapy.
Amitava Majumdar   +24 more
core   +1 more source

Monte Carlo calculation of beam quality correction factors in proton beams using detailed simulation of ionization chambers [PDF]

open access: yes, 2016
This work calculates beam quality correction factors (k Q) in monoenergetic proton beams using detailed Monte Carlo simulation of ionization chambers. It uses the Monte Carlo code penh and the electronic stopping powers resulting from the adoption of two
Andreo Hernández, Pedro   +2 more
core   +2 more sources

A portable graphite calorimeter for onsite reference dosimetry and beam quality correction factor determination

open access: yesJournal of Applied Clinical Medical Physics, Volume 26, Issue 12, December 2025.
Abstract Purpose To present a portable, reliable, and fast setup graphite calorimeter for onsite absolute dose measurements at hospitals. Methods We have designed and built a portable graphite calorimeter optimized for fast setup and accurate measurements at clinical centers. Our system has minimum readout and auxiliary electronics and is inserted in a
Nicolás Gómez‐Fernández   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy